TITLE

Miniaturized dynamic liquid–liquid extraction of organophosphate triesters from blood plasma using the hollow fibre-based XT-tube extractor

AUTHOR(S)
Jonsson, Ove B.; Nilsson, Ulrika L.
PUB. DATE
September 2003
SOURCE
Analytical & Bioanalytical Chemistry;Sep2003, Vol. 377 Issue 1, p182
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A miniaturized liquid–liquid extractor for bioanalytical sample preparation is described. The extractor consists of a polypropylene hollow fibre mounted inside polytetrafluoroethylene (PTFE) tubing by means of a cross (X) connector and a tee (T) connector. All parts are commercially available, inexpensive, and easily assembled. The aqueous sample, injected into a carrier flow, is pumped along the outside of the fibre and the organic phase, which also wets the pores of the hollow fibre wall, is pumped inside. Eight organophosphate triester (OPE) plasticisers/flame retardants were extracted from 50 µL spiked blood plasma that had been mixed with 50 µL formic acid to denature plasma proteins. The organic phase was a mixture of hexane and methyl tert-butyl ether (MTBE). A high concentration of formic acid in the sample and of MTBE in the organic phase had positive effects on the recovery of some OPE. When investigating the recovery as a function of extraction time it was found that the extraction reached a maximum after 10 min, at a flow-rate of 15 µL min-1. Recoveries varied between 40 and 80% with RSD around 4% for most compounds. The whole 150-µL extract was injected into a GC–MS system equipped with a programmed-temperature vaporization (PTV) injector. With the MS in selected-ion monitoring (SIM) mode, the LOD for triphenyl phosphate and 2-ethylhexyl diphenyl phosphate were 0.3 and 0.2 ng mL-1, respectively. More than 40 plasma extractions were performed with the same fibre without any detectable change in extraction efficiency.
ACCESSION #
15125863

 

Related Articles

  • Direct determination of trace refractory elements in human serum by ETV–ICP–MS with in-situ matrix removal. Shengqing Li; Bin Hu; Zucheng Jiang; Rui Chen // Analytical & Bioanalytical Chemistry;Aug2004, Vol. 379 Issue 7/8, p1076 

    A method for in-situ removal of matrix is proposed for direct determination of trace refractory elements in human serum by ETV-ICP-MS with the use of poly(tetrafluoroethylene) (PTFE) as fluorinating re-agent. Attention has been paid to investigating the vaporization behavior both of refractory...

  • Vacuum Deposition of Thin Teflon-Like Films from a Supersonic C2F4 Jet. Rebrov, A. K.; Timoshenko, N. I.; Shishkin, A. V. // Doklady Physics;Dec2004, Vol. 49 Issue 12, p739 

    This article reports that teflon-like films are produced by deposition from a gas-phase of various fluorocarbons and their mixtures or fragments of polytetrafluoroethylene with various-size molecular chains. The experiments were carried out using a gasdynamic low-density setup belonging to the...

  • Electrical properties of flash-evaporated carbon nanolayers on PTFE. Hubáček, T.; Lyutakov, O.; Rybka, V.; Švorčík, V. // Journal of Materials Science;Jan2010, Vol. 45 Issue 1, p279 

    The article presents a study which examines the electrical properties of flash-evaporated carbon nanolayers on polytetrafluoroethylene (PTFE). Researchers found that the electrical resistance of the carbon layers deposited onto PTFE via flash evaporation was measured as a function of the sample...

  • SAFETY CONCERNS STICK TO TEFLON? Hurt, Avery // Better Homes & Gardens;Apr2006, Vol. 84 Issue 4, p274 

    The article clarifies issues related to the use of perfluorooctanoic acid in the manufacture of Teflon and other nonstick cookware in the U.S. Several studies failed to prove the fact that these cookware may be harmful to humans. However, Tee Guidotti, president of the American College of...

  • Spectroscopic Investigation of Sublimated Products of Ultradisperse Polytetrafluoroethylene. Ignatieva, L.; Tsvetnikov, A.; Gorbenko, O.; Kaidalova, T.; Buznik, V. // Journal of Structural Chemistry;Sep2004, Vol. 45 Issue 5, p786 

    The structure of fractions isolated by thermal sublimation of ultradisperse polytetrafluoroethylene (UPTFE) powder has been studied by IR spectroscopy. At 50�C�160�C, fractions of highly amorphous fragments are condensed on a cold receiver; the fragments are constructed from...

  • Loss of Particle Nitrate from Teflon Sampling Filters: Effects on Measured Gravimetric Mass in California and in the IMPROVE Network. Ashbaugh, Lowell L.; Eldred, Robert A. // Journal of the Air & Waste Management Association (Air & Waste M;Jan2004, Vol. 54 Issue 1, p93 

    The extent of mass loss on Teflon filters caused by ammonium nitrate volatilization can be a substantial fraction of the measured particulate matter with an aerodynamic diameter less than 2.5 �m (PM[sub2.5]) or 10 �m (PM[sub10]) mass and depends on where and when it was collected....

  • Adhesive properties of plasma-modified polytetrafluoroethylene films. Yablokov, M.; Kechek’yan, A.; Bazhenov, S.; Gil’man, A.; Piskarev, M.; Kuznetsov, A. // High Energy Chemistry; 

    A procedure was developed for the determination of the adhesion characteristics of the modified surface of thin polymer films, including those treated in a low-temperature plasma, with the use of the Scotch® 810 adhesive tape. The procedure comprises coating the surface to be studied by...

  • Nonstick pans.  // Restaurant Business;11/1/2005, Vol. 104 Issue 15, p82 

    The article presents information related to nonstick pans. When nonstick pans first hit the market in the early 1960s, nonstick coating was applied to pans that had been scoured, creating lots of peaks and valleys, which trapped the nonstick molecules, known as polytetrafluoroethylene, or PTFE....

  • Optimal covering material for stent-grafts placed in the portal vein in a canine model. Ishii, Seigo; Sato, Morio; Sonomura, Tetsuo; Yamada, Katsuyuki; Tanihata, Hirohiko; Ishikawa, Hime; Terada, Masaki; Sahara, Shinya; Kawai, Nobuyuki; Kimura, Masashi; Mori, Ichiro // CardioVascular & Interventional Radiology;Sep2005, Vol. 28 Issue 5, p624 

    Purpose: We evaluated the suitability of Dacron, polytetrafluoroethylene (PTFE), and small intestinal submucosa (SIS) as a covering material for stent-grafts placed in the portal vein as compared with a bare stent. Methods: Using 24 beagle dogs, either bare stents or...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics