TITLE

Simultaneous micellar liquid chromatographic analysis of seven water-soluble vitamins: optimization using super-modified simplex

AUTHOR(S)
Ghorbani, Ali R.; Momenbeik, Fariborz; Khorasani, Jafar H.; Amini, Mohammad K.
PUB. DATE
June 2004
SOURCE
Analytical & Bioanalytical Chemistry;Jun2004, Vol. 379 Issue 3, p439
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A super-modified simplex (SMS) method has been used to optimize the mobile phase used for separation of seven water-soluble vitamins in multivitamin tablets by gradient micellar liquid chromatography (MLC) with ultraviolet (UV) detection at 254, 295, and 361 nm. Effect of column temperature and addition of organic modifier to the mobile phase on separation efficiency were investigated: the appropriate conditions used were a temperature of 35°C and 1-butanol modifier. The sodium dodecyl sulfate (SDS) concentration, pH, and 1-butanol% in the mobile phase were chosen for simultaneous optimization using the SMS method. The optimum mobile phase was found to be 16 mmol L-1 (mM) SDS, 0.02 M phosphate buffer, pH 3.6, and a gradient of 3.5–10% (v/v) butanol. The total analysis time for vitamins was 75 min. The analytical parameters including linearity (r>0.9970), limit of detection (0.12–50 µg mL-1), precision of method (relative standard deviation (RSD) <8.90%), and accuracy obtained by the recovery assay (88–103%) support the usefulness of the proposed method for the determination of the water-soluble vitamins.
ACCESSION #
15125116

 

Related Articles

  • A novel RP-HPLC method for the quantification of lornoxicam in formulations. Devanaboyina, Narendra; Satyanarayana, T.; Rao, B. Ganga // Journal of Pharmacy Research;Dec2011, Vol. 4 Issue 12, p4741 

    A simple, precise and accurate RP-HPLC method was developed and validated for rapid assay of Lornoxicam in tablet dosage form. Isocratic elution at a flow rate of 1.0ml/min was employed on a symmetry Chromosil C18 (250x4.6mm, 5µm in particle size) at ambient temperature. The mobile phase...

  • A New Method for Estimating the Efficiency of Chromatographic Columns. Trzeszczynski, J.; Dzieciol, M. // Journal of Analytical Chemistry;Aug2005, Vol. 60 Issue 8, p723 

    A new method for estimating the efficiency of chromatographic columns by means of the absolute number of its theoretical plates ( N A) is proposed. The absolute number of its theoretical plates can be easily determined from the dependence of the peak width at half height on the retention time....

  • Method Transfer Problems. Dolan, John W. // LC-GC Europe;Jun2008, Vol. 21 Issue 6, p328 

    The article explores a problem related to the transfer of a method from one instrument to another in chromatographic analysis. It discusses how to troubleshoot this liquid chromatography (LC) problem. It suggests that a periodic system performance qualification test be performed for each LC...

  • UPLC SCREENING TO PREPARATIVE HPLC USING CSH COLUMN TECHNOLOGY AND FOCUSED GRADIENTS.  // Lab Manager Magazine;May2012, Vol. 7 Issue 4, p111 

    The article demonstrates the effectiveness of ultra performance liquid chromatography (UPLC) screening protocol to preparative high-performance liquid chromatography (HPLC) using charged-surface hybrid (CSH) column and focused gradients. It states that CSH column is used for its improved peak...

  • HPLC columns.  // LC-GC North America;Dec2005, Vol. 23 Issue 12, p1298 

    The article evaluates the Cogent Qx2 quick-connect HPLC columns from MicroSolv Technology Corp. and offers information on its polar compound retaining capacity and other features.

  • The Retention Behaviour of Reversed-Phase HPLC Columns When Used Under Water 100% Aqueous Mobile-Phase Conditions. Enami, Toshiyuki; Nagae, Norikazu; Doshi, Sid // LC-GC Europe;Jul2003, Vol. 16 Issue 7, p418 

    Studies the retention behavior of reversed-phase high performance liquid chromatography (HPLC) columns under 100% aqueous mobile-phase conditions. Behaviors of reversed-phase HPLC columns; Retention times of the HPLC columns; Criteria for achieving reproducible results from reversed-phase...

  • Core-Shell Particles for HPLC -- Present and Future.  // LC-GC North America;Apr2014, Vol. 32 Issue 4, p302 

    An excerpt from the article "Core-Shell Particles for HPLC-Present and Future" that was published in the previous issue of "CHROMacademy.com" is presented which focuses on the theory and practice of core-shell particles for high performance liquid chromatography (HPLC).

  • Erratum to: Evaluation of ultra high performance liquid chromatography columns for the analysis of unmodified and antisense oligonucleotides. Studzińska, Sylwia; Buszewski, Bogusław // Analytical & Bioanalytical Chemistry;Nov2014, Vol. 406 Issue 28, p7407 

    A correction to the article "Evaluation of ultra high performance liquid chromatography columns for the analysis of unmodified and antisense oligonucleotides" that was published in the September 26, 2014 issue is presented.

  • DEVELOPMENT OF A NEW RP-HPLC METHOD FOR THE ESTIMATION OF NEVIRAPINE IN TABLET DOSAGE FORM. RAVISANKAR, P.; DEVALA RAO, G. // International Journal of Pharmacy & Pharmaceutical Sciences;2013 Supplement, Vol. 5 Issue Supp 3, p505 

    Objective: To develop a selective, sensitive and accurate new reverse phase high performance liquid chromatography method with UV detection and determination for estimation of Nevirapine in tablet formulation. Experimental: The separation and quantification was achieved by Welchrom C18 isocratic...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics