ABSTRACT
Matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry (MS) has proved to be a useful method for the quantification of bile acids directly from plasma. Six cholic acid derivatives were selected for analysis: taurocholic acid, taurochenodeoxycholic acid, taurolithocholic acid, glycocholic acid, glycochenodeoxycholic acid, and glycolithocholic acid. Solid-phase extraction (SPE) columns were used to preconcentrate and purify the plasma samples. Calibration curves averaged from 3 days were obtained for the bile acids, and then tested for their ability to accurately determine concentrations from one measurement. In summary, a simple, rapid method has been developed for the quantification of bile salts from plasma by MALDI-MS with SPE cleanup.
ACCESSION #
15124914

 

Related Articles

  • Temporal development of the plasma composition of a pulsed aluminum plasma stream in the presence... Schneider, Jochen M.; Anders, Andre; Brown, Ian G.; Hjorvarsson, Bjorgvin; Hultman, Lars // Applied Physics Letters;8/2/1999, Vol. 75 Issue 5, p612 

    Describes the temporal development of the plasma composition of pulsed aluminum plasma streams at various oxygen pressures. Formation of the plasma with a vacuum arc plasma source; Measurement of time resolved plasma composition with time-of-flight charge-to-mass spectrometry; Role of oxygen...

  • Plasma temperatures from first-hit neutron time-of-flight spectra. Lerche, R. A.; Hatchett, S. P.; Cable, M. D.; Nelson, M. B.; Murphy, T. J. // Review of Scientific Instruments;Oct92, Vol. 63 Issue 10, p4877 

    We describe a new technique for determining an inertial-confinement-fusion plasma temperature from a neutron time-of-flight spectrum recorded with a multielement detector array—even when each array element becomes fully saturated. A temperature uncertainty <20% is achieved over a yield...

  • High brightness extreme ultraviolet (at 13.5 nm) emission from time-of-flight controlled discharges with coaxial fuel injection. Hosokai, Tomonao; Yokoyama, Takuma; Zhidkov, Alexei; Sato, Hiroto; Horioka, Kazuhiko; Hotta, Eiki // Journal of Applied Physics;Sep2008, Vol. 104 Issue 5, p053305 

    Extreme ultraviolet (EUV) emission from discharge produced plasma with the coaxial injection of fuel vapor (tin and lithium) produced by laser ablation is experimentally studied. Multiple plasma pinches preceding a strong and long recombination radiation of EUV are observed in the first half...

  • Time-of-flight energy analyzer for the plasma potential measurements by a heavy ion beam diagnostic. Nedzelskiy, I. S.; Malaquias, A.; Gonçalves, B.; Silva, C.; Varandas, C. A. F.; Cabral, J. A. C. // Review of Scientific Instruments;Oct2004 Part I & II, Vol. 75 Issue 10, p3514 

    A time-of-flight (TOF) technique for the plasma potential measurements by a heavy ion beam diagnostic (HIBD) with a multiple cell array detector has been elaborated on tokamak ISTTOK as an alternative to the traditional electrostatic energy analyzer. This article describes the design and...

  • Isolation and LC-MS Characterization of Illicit Bath Salts in Urine. Aurand, Craig // LC-GC North America;Feb2013 Supplement, Vol. 31, p10 

    The article discusses the analysis of bath salts from the samples of urine. Various methods are employed for analysis are mentioned including sample preparation by solid phase extraction (SPE), Hydrophilic interaction chromatography (HILIF) and Time of flight-Mass spectroscopy (TOF-MS)....

  • High count rate time-of-flight spectrometer for DD fusion neutrons. Gorini, G.; Källne, J. // Review of Scientific Instruments;Oct92, Vol. 63 Issue 10, p4548 

    The basic factors setting the performance limits of the time-of-flight (TOF) spectrometer for 2.5-MeV neutrons as used for tokamak plasma diagnostics are analyzed. Special scintillator designs are proposed for best performance. Examples of diagnostic uses of the TOF spectrometer are also given.

  • Axial ion charge state distribution in the vacuum arc plasma jet. Keidar, M.; Brown, I. G.; Beilis, I. I. // Review of Scientific Instruments;Feb2000, Vol. 71 Issue 2, p698 

    Focuses on results of some experimental investigations of the axial ion charge state distribution (CSD) using a time-of-flight diagnostic. Dependence of the CSD on the axial distance from the plasma source region; Description of a model for the plasma jet expansion.

  • Ion charge state distributions of pulsed vacuum arc plasmas in strong magnetic fields Anders, Andre; Yushkov, George; Oks, Efim; Nikolaev, Alexey; Brown, Ian // Review of Scientific Instruments;Mar98, Vol. 69 Issue 3, p1332 

    Examines the ion charge state distributions of pulsed vacuum arc plasmas in strong magnetic fields through time-of-flight mass spectroscopy. Details on the discharge currents and duration of vacuum arc plasmas; Process for enhancing ion charge states; Attribution of increased plasma temperatures...

  • Monte Carlo method for neutron spectrum recovery - a new approach based on the accelerated ions distribution. Ivanova-Stanik, I. M.; Miklaszewski, R. // European Physical Journal D -- Atoms, Molecules, Clusters & Opti;Jan2010, Vol. 54 Issue 2, p293 

    New method of neutron spectrum recovery described in the paper involves accelerated deuterons (that produce neutrons in DD reaction) and allows getting neutron spectrum in any direction from computed time-velocity $(t, \textbf{V})$ characteristics of deuterons. Time of flight signals registered...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics