TITLE

Measurement of isotope ratios on transient signals by MC-ICP–MS

AUTHOR(S)
Günther-Leopold, Ines; Wernli, Beat; Kopajtic, Zlatko; Günther, Detlef
PUB. DATE
January 2004
SOURCE
Analytical & Bioanalytical Chemistry;Jan2004, Vol. 378 Issue 2, p241
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Precise and accurate isotope ratio measurements are an important task in many applications such as isotope-dilution mass spectrometry, bioavailability studies, or the determination of isotope variations in geological or nuclear samples. The technique of MC-ICP–MS has attracted much attention because it permits the precise measurement of isotope compositions for a wide range of elements combined with excellent detection limits due to high ionisation efficiencies. However, the results are based mainly on measurements using continuous sample introduction. In the present study the determination of isotope ratios on various transient signals with a time duration of 30 to 60 s has been achieved by coupling high-performance liquid chromatography to a multicollector inductively coupled plasma mass spectrometer. In order to investigate the origin of ratio drifts across the transient signals for this hyphenated technique, measurements with the same standard solutions were also carried out using a flow-injection device for sample introduction. As a result of this application it could be concluded that the main source of the bias in the measured isotope ratios is within the ICP–MS instead of fractionation effects on the chromatographic column material. Preliminary studies on short transient signals of gaseous samples (dry plasma) showed a reverse fractionation effect compared with wet plasma conditions (flow injection and HPLC).
ACCESSION #
15124842

 

Related Articles

  • Isotope-abundance ratios of light (bio) and heavy (geo) elements in biogenic tissues: methods and applications. Hölzl, Stefan; Horn, Peter; Rossmann, Andreas; Rummel, Susanne // Analytical & Bioanalytical Chemistry;Jan2004, Vol. 378 Issue 2, p270 

    The article presents a report on isotope-abundance ratios of light and heavy elements in biogenic tissues. In the fields of pure biochemistry, radiochemistry, agriculture, hydrology, geo- and cosmochemistry, and, especially, geochronometry mass spectrometry has conventionally been used to...

  • Comparison of electron ionization mass spectra of some organic compounds (MW < 200 Da) recorded on mass spectrometers of various types. Samokhin, A.; Revel'skii, A.; Revel'skii, I. // Journal of Analytical Chemistry;Dec2011, Vol. 66 Issue 14, p1432 

    Low-resolution electron ionization mass spectra recorded on various types of mass spectrometers (time-of-flight, quadrupole, and three-dimensional ion trap) were compared. A model mixture of 10 organic compounds (MW < 200 Da) was analyzed by gas chromatography-mass spectrometry. Pure mass...

  • Chromatography Market Profile: Mass Spectrometry.  // LC-GC North America;Apr2008, Vol. 26 Issue 4, p332 

    The article focuses on mass spectrometry (MS), one of the most versatile and powerful instrument techniques in the U.S. The new mass spectrometer techniques include various tandem MS techniques and applications continue to be developed and are being used by many MS users. It offers various...

  • Interpretation of Isotope Peaks in all Molecule LC--MS. Hill, Lionel M. // LC-GC Europe;Apr2006, Vol. 19 Issue 4, p226 

    Biologists entering liquid chromatography-mass spectrometry (LC-MS) from a background of general LC rarely use their mass spectrometer to its full potential. Isotope peaks offer huge possibilities both in semi-quantitative interpretation of structure and in quantitative labelling studies. This...

  • Comparison of Ion Trap and Q-TOF Mass Spectrometers for Protein Identification. Second, Tonya Pekar; Blethrow, Justin; Schwartz, Jae C.; Zabrouskov, Viad // LC-GC North America;Sep2009 Application Notebook, Vol. 27, p16 

    The article reports on the result of the study which provides a comparison on the effectiveness of Thermo Scientific LTQ Velos ion trap and Agilent 6520 quadrupole time-of-flight (Q-TOF) mass spectrometers in identifying proteins of Caenorhabditis (C) elegans. The study focused on the...

  • Highest Data Content Together with Highest Throughput--The Agilent 1200 Series Rapid Resolution LC System and The Agilent 6210 Time-of-Flight MS. Frank, Michael // LC-GC Europe;Jul2006 Supplement, p35 

    With the introduction of an LC-MS system which facilitates the use of columns with sub-2 �m particles it is now possible to achieve short analysis times as well as high chromatographic resolution. Furthermore, the system from Agilent Technologies is able to acquire full UV spectral data and...

  • Emerging Technologies in the Mass Spectrometry Arsenal. Balogh, Michael P. // Spectroscopy;Feb2005, Vol. 20 Issue 2, p54 

    Provides an overview of several recently developed technologies that will improved the utility and performance of mass spectrometers in a number of applications. Photoionization; Ion mobility techniques; Ultrahigh-pressure chromatography.

  • Convenient synthesis of 3,5-disubstituted N-Salicylidene-4-allyloxyanilines. Oleinik, I.; Ivanchev, S.; Tolstikov, G. // Russian Journal of Organic Chemistry;Dec2010, Vol. 46 Issue 12, p1888 

    The article discusses the alternative approach for the synthesis of Schiff bases I. It mentions the adoption of salicylidene protection of the amino group that includes the chemical reaction of 3,5-disubstituted salicylaldehydes IIa and IIb with p-aminophenol. It states that flash chromatography...

  • Ion trap LC-MS.  // LC-GC Europe;Jan2006, Vol. 19 Issue 1, p52 

    The article presents information about Varian 500-MS LC Ion Trap, a new liquid chromatograph/mass spectrometer from Varian Inc. The spectrometer comes with several technology advancements which enable the analysis of thermally labile compounds, such as drug metabolites, pesticides and herbicides.

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics