Overcoming spectral overlap in isotopic analysis via single- and multi-collector ICP–mass spectrometry

AUTHOR(S)
Vanhaecke, Frank; Luc Moens
PUB. DATE
January 2004
SOURCE
Analytical & Bioanalytical Chemistry;Jan2004, Vol. 378 Issue 2, p232
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
For isotope ratio applications where an internal isotope ratio precision >0.05–0.1% relative standard deviation suffices, single-collector inductively coupled plasma mass spectrometry (ICPMS) is fit-for-purpose, but for detecting more subtle variations in the natural isotopic composition of a target element, only multi-collector ICPMS (MC-ICPMS) can compete with thermal ionization mass spectrometry (TIMS). While as a result of the extensive sample preparation (analyte isolation) preceding TIMS and the "softer" ionization in vacuum, spectral interferences only seldom occur with this technique, their occurrence is recognized to be the most important drawback of ICPMS. This paper discusses high mass resolution and chemical resolution in a collision or dynamic reaction cell as powerful and versatile means to overcome spectral overlap and illustrates how their introduction has led to a substantial extension of the application range of ICPMS for isotope ratio applications. High mass resolution is the most elegant and straightforward way to overcome the problem of spectral overlap. Offering the possibility to operate the mass analyzer at a higher mass resolution, while at the same time preserving the flat-topped or trapezoidal peak shape required for highly precise isotope ratio measurements, was a challenge for the manufacturers of MC-ICPMS instrumentation. It will be discussed how these apparently contradicting requirements could be fulfilled simultaneously and an overview of the current situation will be given. Chemical resolution in a collision or dynamic reaction cell is an alternative to high mass resolution for overcoming spectral overlap. Real-life examples will be given to illustrate how also this approach can be used to advantage in isotope ratio work. Despite the greater flexibility and straightforwardness of high mass resolution, some situations will be discussed where chemical resolution is to be preferred. Finally, some desires as to future instrumentation are formulated.
ACCESSION #
15124838

 

Related Articles

  • The secret of NIMS. Doerr, Allison // Nature Methods;Dec2007, Vol. 4 Issue 12, p985 

    A new mass spectrometry surface-based ionization method offers up advantages in sensitivity and the ability to directly analyze biological samples, especially for metabolomics studies.

  • Recent problems and advances in mass spectrometry (Review). Lebedev, A.; Zaikin, V. // Inorganic Materials;Dec2008, Vol. 44 Issue 14, p1482 

    Advances in mass spectrometry, including the ionization and ion-separation methods, and its applications in various branches of science and human activity are overviewed.

  • Determination of femtogram quantities of 239Pu and 240Pu in bioassay samples by thermal ionization mass spectrometry. Elliot, N. L.; Bickel, G. A.; Linauskas, S. H.; Paterson, L. M. // Journal of Radioanalytical & Nuclear Chemistry;Mar2006, Vol. 267 Issue 3, p637 

    A thermal ionization mass spectrometry (TIMS) method is described for the determination of ultra-trace levels of plutonium isotopes in human urine samples. The method has been validated through the analysis of artificial urine samples spiked with known amounts of 239Pu ranging from 2.5 fg to 50...

  • Nanomaterials in mass spectrometry ionization and prospects for biological application. Zhong Guo; Ganawi, Amel A. A.; Qiang Liu; Lin He // Analytical & Bioanalytical Chemistry;Jan2006, Vol. 384 Issue 3, p584 

    The rapid development of nanotechnology has revolutionized scientific developments in recent decades. Mass spectrometry (MS) measurements are no exception and have benefited greatly from integration of nanomaterials in every step of analysis. This brief review summarizes recent developments in...

  • The use of ICPMS for stable isotope tracer studies in humans: a review. Stürup, Stefan // Analytical & Bioanalytical Chemistry;Jan2004, Vol. 378 Issue 2, p273 

    The use of stable isotope tracers in human studies is a rapidly growing research field that benefits from the many new developments in inorganic mass spectrometric instrumentation and from the better availability of mass spectrometric techniques to nutritional scientists during the last three...

  • Ultratrace analysis and isotope ratio measurements of long-lived radioisotopes by resonance ionization mass spectrometry (RIMS). Trautmann, N.; Passler, G.; Wendt, K. D. A. // Analytical & Bioanalytical Chemistry;Jan2004, Vol. 378 Issue 2, p348 

    Resonance Ionization Mass Spectrometry (RIMS) is a sensitive and selective method for ultratrace analysis of long-lived radioisotopes and isotope ratio measurements. It provides extremely high isobaric suppression and good overall efficiency. The experimental limits of detection are as low as...

  • Organic mass spectrometry at the beginning of the 21st century. Lebedev, A.; Zaikin, V. // Journal of Analytical Chemistry;Dec2008, Vol. 63 Issue 12, p1128 

    Mass spectrometry in the last 15–20 years has become one of the first methods of the qualitative analysis and quantitative determination of various substances, from isotopes of chemical elements to synthetic polymers, proteins, and nucleic acids. This method allows analysts to work with...

  • Isotopic variation of experimental lifetimes for the lowest 1Πu states of N2. Sprengers, J. P.; Ubachs, W.; Baldwin, K. G. H. // Journal of Chemical Physics;4/8/2005, Vol. 122 Issue 14, p144301 

    Lifetimes of several 1Πu states of the three natural isotopomers of molecular nitrogen, 14N2, 14N15N, and 15N2, are determined via linewidth measurements in the frequency domain. Extreme ultraviolet (XUV)+UV two-photon ionization spectra of the b 1Πu(v=0–1,5–7) and...

  • New interface plate for microspray ionization mass spectrometry. Li Zhou; Lailiang Zhai; Bingfang Yue; Lee, Edgar D.; Lee, Milton L. // Analytical & Bioanalytical Chemistry;Aug2006, Vol. 385 Issue 6, p1087 

    A new interface plate was employed in microspray ionization mass spectrometry (μESI-MS) to improve ion transmission from the sprayer into the sampling nozzle of the mass spectrometer at atmospheric pressure. Using a time-of-flight mass spectrometer (TOFMS), a fivefold increase in ion...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics