TITLE

An electronic tongue using potentiometric all-solid-state PVC-membrane sensors for the simultaneous quantification of ammonium and potassium ions in water

AUTHOR(S)
Gallardo, J.; Alegret, S.; Mu�oz, R.; De-Rom�n, M.; Leija, L.; Hern�ndez, P. R.; del Valle, M.
PUB. DATE
September 2003
SOURCE
Analytical & Bioanalytical Chemistry;Sep2003, Vol. 377 Issue 2, p248
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The simultaneous determination of NH4+ and K+ in solution has been attempted using a potentiometric sensor array and multivariate calibration. The sensors used are rather non-specific and of all-solid-state type, employing polymeric (PVC) membranes. The subsequent data processing is based on the use of a multilayer artificial neural network (ANN). This approach is given the name "electronic tongue" because it mimics the sense of taste in animals. The sensors incorporate, as recognition elements, neutral carriers belonging to the family of the ionophoric antibiotics. In this work the ANN type is optimized by studying its topology, the training algorithm, and the transfer functions. Also, different pretreatments of the starting data are evaluated. The chosen ANN is formed by 8 input neurons, 20 neurons in the hidden layer and 2 neurons in the output layer. The transfer function selected for the hidden layer was sigmoidal and linear for the output layer. It is also recommended to scale the starting data before training. A correct fit for the test data set is obtained when it is trained with the Bayesian regularization algorithm. The viability for the determination of ammonium and potassium ions in synthetic samples was evaluated; cumulative prediction errors of approximately 1% (relative values) were obtained. These results were comparable with those obtained with a generalized regression ANN as a reference algorithm. In a final application, results close to the expected values were obtained for the two considered ions, with concentrations between 0 and 40 mmol L-1.
ACCESSION #
15124710

 

Related Articles

  • Array of potentiometric sensors for multicomponent analysis of blood serum. Correia, Daniela P. A.; Magalhães, Júlia M. C. S.; Machado, Adélio A. S. C. // Microchimica Acta;Sep2008, Vol. 163 Issue 1/2, p131 

    Two urea biosensors, based on carboxylated polyvinylchloride ammonium ion selective electrodes with urease immobilized with carbodiimide, were included in an array together with potassium and sodium ion selective electrodes and evaluated for simultaneous determination of urea and potassium in...

  • A neural network approach for on-line fault detection of nitrogen sensors in alternated active sludge. F. Caccavale; P. Digiulio; M. Iamarino; S. Masi; F. Pierri // Water Science & Technology;2010, Vol. 62 Issue 12, p2760 

    In this paper, an effective strategy for fault detection of nitrogen sensors in alternated active sludge treatment plants is proposed and tested on a simulated set-up. It is based on two predictive neural networks, which are trained using a historical set of data collected during fault-free...

  • Cetrimide Potentiometric PVC membrane Sensor. Faridbod, Farnoush; Khamseh-nejad, Masoumeh; Ganjali, Mohammad Reza; Norouzi, Parviz; Hajiaghababaei, Leila // International Journal of Electrochemical Science;2012, Vol. 7 Issue 3, p1917 

    In the present work, two types of potentiometric electrodes were constructed for determination of cetrimide. The sensors demonstrated advanced performances with a fast response time, a lower detection limit of 4.0x10-6 M and potential responses across the range of 5.0x10-6-1.0x10-3 M. The ensors...

  • Fabrication of an Y3+-PVC Membrane Sensor Based on Dicyclohexyl-18-Crown-6 for Determination Fluoride Ion. Kazemi, Malihe Samadi; Ashraf, Narges // International Journal of Electrochemical Science;Jul2011, Vol. 6, p2955 

    In this research, construction and performance characteristics of a PVC membrane electrode based on dicylohexyl-18-crown-6 (DCH18C6) as a neutral ionophore have been described. The influence of the membrane composition on the potentiometric response of the electrode has been investigated and...

  • Construction of a Highly Selective and Sensitive Ytterbium(III) Membrane Sensor Based on 4-Methoxybenzyl Carbazate as a New Neutral Ionophore. Zamani, Hassan Ali; Sahebnasagh, Sara // International Journal of Electrochemical Science;Mar2013, Vol. 8 Issue 3, p3429 

    In this research, 4-Methoxybenzyl carbazate (MBC) was used as an excellent sensing ion carrier in the construction of a poly vinyl chloride membrane sensor for Yb3+ ions. The electrode shows a good selectivity for the Yb3+ ion with respect to most common cations including alkali, alkaline earth,...

  • A polypyrrole-based solid-contact Pb2+-selective PVC-membrane electrode with a nanomolar detection limit. Sutter, Jolanda; Lindner, Ernö; Gyurcsãnyi, Robert E.; Pretsch, Ernö // Analytical & Bioanalytical Chemistry;Sep2004, Vol. 380 Issue 1, p7 

    Ion-selective electrodes (ISE) based on conventional plasticized PVC membranes with solid inner contact (SC) have so far had unsatisfactory lower detection limits. Here it is shown that electropolymerization of pyrrole in the presence of potassium hexacyanoferrate(II)/(III) on Pt results in...

  • SINGLE-IMAGE SUPER RESOLUTION FOR MULTISPECTRAL REMOTE SENSING DATA USING CONVOLUTIONAL NEURAL NETWORKS. Liebel, L.; Körner, M. // International Archives of the Photogrammetry, Remote Sensing & S;2016, Vol. 41 Issue B3, p883 

    In optical remote sensing, spatial resolution of images is crucial for numerous applications. Space-borne systems are most likely to be affected by a lack of spatial resolution, due to their natural disadvantage of a large distance between the sensor and the sensed object. Thus, methods for...

  • Potentiometric PVC Membrane Sensor for the Determination of Phenylephrine Hydrochloride in Some Pharmaceutical Products. Giahi, M.; Mirzaei, M.; Veghar Lahijani, G. // Journal of the Iranian Chemical Society;Jun2010, Vol. 7 Issue 2, p333 

    A new PVC membrane electrode for the determination of phenylephrine hydrochloride based on the formation of an ionassociation complex of phenylephrine hydrochloride with the phosphotungstate counter anion as an electroactive material dispersed in a PVC matrix is described. The sensor shows a...

  • Detection of Runaway Reaction in a Polyvinyl Chloride Batch Process Using Artificial Neural Networks. Ardi, S.; Minowa, H.; Suzuki, K. // International Journal of Performability Engineering;Jul2009, Vol. 5 Issue 4, p367 

    In this paper, the method of detecting a runaway reaction in a batch process using artificial neural network (ANN) model is proposed. From the safety point of view, it is difficult to investigate what the causes of runaway reactions in the chemical plants are, besides as the consequences of the...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library