TITLE

Comparison of biosensors based on entrapment of cholesterol oxidase and cholesterol esterase in electropolymerized films of polypyrrole and diaminonaphthalene derivatives for amperometric determination of cholesterol

AUTHOR(S)
Vidal, J. C.; Garcia-Ruiz, E.; Espuelas, J.; Aramendia, T.; Castillo, J. R.
PUB. DATE
September 2003
SOURCE
Analytical & Bioanalytical Chemistry;Sep2003, Vol. 377 Issue 2, p273
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Cholesterol amperometric biosensors constructed with enzymes entrapped in electropolymerized layers of polypyrrole and poly-naphthalene derivative polymers are compared. The biosensors are based on entrapment of cholesterol oxidase and/or cholesterol esterase in monolayer or multilayer films electrochemically synthesised from pyrrole, 1,8-diaminonaphthalene (1,8-DAN), and 1,5-diaminonaphthalene (1,5-DAN) monomers. Seven configurations were assayed and compared, and different analytical properties were obtained depending on the kind of polymer and the arrangement of the layers. The selectivity properties were evaluated for the different monolayer and bilayer configurations proposed as a function of the film permeation factor. All the steps involved in the preparation of the biosensors and determination of cholesterol were carried out in a flow system. Sensitivity and selectivity depend greatly on hydrophobicity, permeability, compactness, thickness, and the kind of the polymer used. In some cases a protective outer layer of non-conducting poly(o-phenylenediamine) polymer improves the analytical characteristics of the biosensor. A comparative study was made of the analytical performance of each of the configurations developed. The biosensors were also applied to the flow-injection determination of cholesterol in a synthetic serum.
ACCESSION #
15124698

 

Related Articles

  • Tailored polymer microlenses on treated glass surfaces. Sokuler, Mordechai; Aronov, Daniel; Rosenman, Gil; Gheber, Levi A. // Applied Physics Letters;5/14/2007, Vol. 90 Issue 20, p203106 

    Integrating arrayed biosensors (biochips) or micro- and nanofluidic devices with readout systems is an important step towards their realization in lab-on-a-chip devices. To this end, we present a straightforward method of fabricating polymer microlenses in precise locations, with desired optical...

  • Electrochemical Oxidation of Glucose Using Mutant Glucose Oxidase from Directed Protein Evolution for Biosensor and Biofuel Cell Applications. Yu, Eileen; Prodanovic, Radivoje; Güven, Güray; Ostafe, R.; Schwaneberg, U. // Applied Biochemistry & Biotechnology;Dec2011, Vol. 165 Issue 7/8, p1448 

    In this study, electrochemical characterisation of glucose oxidation has been carried out in solution and using enzyme polymer electrodes prepared by mutant glucose oxidase (B11-GOx) obtained from directed protein evolution and wild-type enzymes. Higher glucose oxidation currents were obtained...

  • Molecularly Imprinted Polymers for Selective Adsorption of Cholesterol from Aqueous Environment. Puoci, Francesco; Iemma, Francesca; Cirillo, Giuseppe; Trombino, Sonia; Cassano, Roberta; Picci, Nevio // e-Polymers;Jan2007, p1 

    In this work the preparation and evaluation of molecularly imprinted polymers (MIPs) based on 2-hydroxyethylmetacrylate (HEMA) for selective recovery of cholesterol from aqueous media are reported. HEMA was used as functional monomer in order to maximize the hydrogen bond forming both in...

  • Electroluminescence and Photoluminescence of Conjugated Polymer Films Prepared by Plasma Enhanced Chemical Vapor Deposition of Naphthalene. Rajabi, M.; Ghassami, A.; Abbasi Firouzjah, M.; Hosseini, S.; Shokri, B. // Plasma Chemistry & Plasma Processing;Aug2013, Vol. 33 Issue 4, p817 

    Polymer light-emitting devices were fabricated utilizing plasma polymerized thin films as emissive layers. These conjugated polymer films were prepared by RF plasma enhanced chemical vapor deposition using naphthalene as monomer. The effect of different applied powers on the chemical structure...

  • Enzyme sensor system for determination of total cholesterol in fish plasma. Endo, Hideaki; Maita, Masashi; Mio Takikawa, Masashi; Huifeng Ren, Masashi; Tetsuhito Hayashi, Masashi; Naoto Urano, Masashi; Kohji Mitsubayashi, Masashi // Fisheries Science;Dec2003, Vol. 69 Issue 6, p1194 

    An enzyme biosensor system was developed for rapid and continuous determination of total cholesterol in fish plasma. The system was constructed with an immobilized enzyme membrane, Clark-type oxygen electrode, flow system and personal computer. The enzyme membrane was prepared from cholesterol...

  • Enzyme-Based Vinyl Polymerization. Singh, Amarjit; Kaplan, David L. // Journal of Polymers & the Environment;Jul2002, Vol. 10 Issue 3, p85 

    In vitro enzyme-mediated polymerization of vinyl monomers is reviewed. Oxidoreductase enzymes have been used for the polymerization of styrene, derivatives of styrene, acrylates, and acrylamide in water and water-miscible co-solvents. Kinetic and mechanistic studies revealed that a ternary...

  • Palm Tree Peroxidases. Sakharov, I. Yu. // Biochemistry (00062979);Aug2004, Vol. 69 Issue 8, p823 

    Over the years novel plant peroxidases have been isolated from palm trees leaves. Some molecular and catalytic properties of palm peroxidases have been studied. The substrate specificity of palm peroxidases is distinct from the specificity of other plant peroxidases. Palm peroxidases show...

  • Electrodeposition polymers as immobilization matrices in amperometric biosensors: improved polymer synthesis and biosensor fabrication. Guschin, Dmitrii A.; Shkil, Halyna; Schuhmann, Wolfgang // Analytical & Bioanalytical Chemistry;Nov2009, Vol. 395 Issue 6, p1693 

    Electrodeposition polymers can be precipitated on electrode surfaces upon electrochemical-induced modulations of the pH value in the diffusion zone in front of the electrode. The formed polymer films can be used as immobilization matrices in amperometric biosensors. In order to rationally...

  • Fabricating an Amperometric Cholesterol Biosensor by a Covalent Linkage between Poly(3-thiopheneacetic acid) and Cholesterol Oxidase. Po-Chin Nien; Po-Yen Chen; Kuo-Chuan Ho // Sensors (14248220);2009, Vol. 9 Issue 3, p1794 

    In this study, use of the covalent enzyme immobilization method was proposed to attach cholesterol oxidase (ChO) on a conducting polymer, poly(3-thiopheneacetic acid), [poly(3-TPAA)]. Three red-orange poly(3-TPAA) films, named electrodes A, B and C, were electropolymerized on a platinum...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics