TITLE

Modern stationary phases for ion chromatography

AUTHOR(S)
Weiss, J.; Jensen, D.
PUB. DATE
January 2003
SOURCE
Analytical & Bioanalytical Chemistry;Jan2003, Vol. 375 Issue 1, p81
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Due to the better understanding of the processes taking place at the surface of the stationary phases, the number of ion-exchange materials for ion chromatography (IC) has increased tremendously over recent years. As a result, the multitude of commercially available columns today with their different selectivities for anion and cation chromatography is almost confusing. Hence, the aim of this article is to describe the different principles determining selectivity and ion-exchange capacity and to classify the various ion-exchange materials accordingly. To ensure a fair comparison of these columns, the selectivity differences are illustrated by showing separations of standards rather than individual samples.
ACCESSION #
15124445

 

Related Articles

  • dibasic.  // Taber's Cyclopedic Medical Dictionary (2009);2009, Issue 21, p643 

    A definition of the term "dibasic," which pertains to the capability of neutralizing or accepting two hydrogen ions, is presented.

  • Source of Negative Hydrogen Ions with Hot Cathode. Kuznetsov, G. I.; Batazova, M. A. // AIP Conference Proceedings;2005, Vol. 763 Issue 1, p275 

    In the report an H- ion source with following parameters is described. Ion energy is up to 30 keV, current is up to 5 mA, pulse duration varies from 1 to tens microseconds. H- ions are produced in magnetron discharge near a hot cathode surface made of LaB6 or IrCe alloy, which is 6 mm in...

  • Volume Production of High Negative Hydrogen Ion Density in Low-Voltage Cesium-Hydrogen Discharge. Baksht, F. G.; Ivanov, V. G.; Shkol'nik, S. M.; Bacal, M. // AIP Conference Proceedings;2005, Vol. 763 Issue 1, p138 

    The work is dedicated to the theoretical and experimental investigation of the intense H- volume-plasma generation in cesium-hydrogen discharge. A low-voltage (LV) mode of the discharge, a LV arc with a heated cathode, is studied. Theory of the discharge was created. It was shown theoretically...

  • A study of iso- and alio-valent cation doped Ag[sub 2] SO[sub 4] solid electrolyte. Singh, K.; Pande, S.M.; Anwane, S.W.; Bhoga, S.S. // Applied Physics A: Materials Science & Processing;1998, Vol. 66 Issue 2, p205 

    Abstract. AC conductivity results are obtained by incorporating various guest iso-valent and alio-valent cations within the solid solubility limit with different ionic radii in both the structural modifications of Ag[sub 2]SO[sub 4]. The solid solubility limits up to x less than or equal to 3...

  • Does Stewart-Fencl approach improve the evaluation of acid-base status in stable patients on haemodiafiltration? Jaras, J. Hernández; Salvador, I. Rico; de Juan, E. Torregrosa; Prades, R. Pons; Peris, A. Rius; Segarra, M. A. Fenollosa; Canel, J.J. Sánchez; Mateo, T. Carbajo // Nefrologia;04/01/2010, Vol. 30 Issue 2, p214 

    Introduction: The traditional evaluation of acid-base status relies on the Henderson-Hasselbach equation. In 1983, an alternative approach, based on physical and chemical principles was proposed by P. Stewart. In this approach, plasma pH is determined by 3 independent variables: pCO2, Strong Ion...

  • Recent Applications of Ionic Liquids in Separation Technology. Dandan Han; Kyung Ho Row // Molecules;Apr2010, Vol. 15 Issue 4, p2405 

    Ionic liquids (ILs) have been applied in different areas of separation, such as ionic liquid supported membranes, as mobile phase additives and surface-bonded stationary phases in chromatography separations and as the extraction solvent in sample preparations, because they can be composed from...

  • Atomic wall recombination and volume negative ion production. Pagano, Damiano; Gorse, Claudine; Capitelli, Mario // Review of Scientific Instruments;Mar2006, Vol. 77 Issue 3, p03A505 

    The development of a numerical code for the modeling of negative ion sources requires the knowledge of a lot of processes occurring both in the gas phase and at the surface. The present work concerns the effect of surface processes (in particular atomic wall recombination) on the kinetics of...

  • Matrix-assisted laser desorption mass spectrometry of gas-phase peptide—metal complexes. Hortal, Ana; Hurtado, Paola; Martínez-Haya, Bruno // Applied Physics A: Materials Science & Processing;Dec2008, Vol. 93 Issue 4, p935 

    Cation attachment to a model peptide has been investigated in matrix-assisted laser desorption experiments. Angiotensin I (Asp–Arg–Val–Tyr–Ile–His–Pro–Phe–His–Leu) is chosen as a system for study, and Cu2+ and K+ salts are used as...

  • Photodetachment spectrum of hydrogen negative ion near a spherical surface. Afaq, A.; Iqbal, A.; Iftikhar, A.; Asif, M. // Canadian Journal of Physics;Feb2016, Vol. 94 Issue 2, p226 

    The semi-classical closed orbit theory is applied to study photodetachment of H− near an elastic spherical surface for a z-polarized laser light. It is assumed that similar to the outgoing detached-electron waves from the source, waves propagate from an image of the source behind the...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics