TITLE

Investigation of the radiation properties of L- and M-shell X-pinch plasma x-ray sources using a transmission grating spectrometer

AUTHOR(S)
Fedin, D. A.; Kantsyrev, V. L.; Shlyaptseva, A. S.; Mitchell, M. D.; Song, B. M.; Pikuz, S. A.; Shelkovenko, T. A.; Chandler, K. M.; Hammer, D. A.; Maxson, L. M.
PUB. DATE
October 2004
SOURCE
Review of Scientific Instruments;Oct2004 Part I & II, Vol. 75 Issue 10, p3711
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A transmission grating spectrometer (TGS) with one dimensional spatial resolution was used to investigate the radiative properties of X-pinch plasmas produced using wires made of NiCr and CoNiCr alloys, and Mo. Experiments were carried out on the Cornell XP machine. The TGS was used to estimate of the energy yields of L-shell Cr and Ni, and M-shell Mo radiation. The absolute energy yields in the wavelength range 10<λ<15 Å were 1–5% of the total energy delivered to the load (10–40 J for L-shell NiCr, and 20–50 J for M-shell Mo). An analysis of the spatial structure of X-pinch emission regions in different wavelength ranges shows that the source structure is changing with wavelength and the size varies from less than 0.1 up to 1 mm. For example, in one Mo X-pinch test shown, three separate soft x-ray sources radiating in the wavelength range λ<42 Å can be seen, but only one of those sources radiates in the wavelength range λ>42 Å. The results are compared with data obtained previously with the TGS on a 1 MA pulse powered machine Zebra.
ACCESSION #
14842259

 

Related Articles

  • A refocusing modified velocity map imaging electron/ion spectrometer adapted to synchrotron radiation studies. Garcia, Gustavo A.; Nahon, Laurent; Harding, Chris J.; Mikajlo, Elisabeth A.; Powis, Ivan // Review of Scientific Instruments;May2005, Vol. 76 Issue 5, p053302 

    We present a modified velocity map imaging (VMI) spectrometer to be used in angle-resolved molecular photoionization studies in the gas phase with synchrotron radiation (SR) in the VUV/soft x-ray range. The main modifications as compared to the original design of Eppink and Parker [A. T. J. B....

  • Super ESCA: First beamline operating at ELETTRA. Abrami, A.; Barnaba, M.; Battistello, L.; Bianco, A.; Brena, B.; Cautero, G.; Chen, Q.H.; Cocco, D.; Comelli, G.; Contrino, S.; DeBona, F.; Di Fonzo, S.; Fava, C.; Finetti, P.; Furlan, P.; Galimberti, A.; Gambitta, A.; Giuressi, D.; Godnig, R. // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p1618 

    Describes the Super-ESCA, a beamline designed for high resolution core level spectroscopy of adsorbates on single crystal surfaces using soft x-ray synchrotron radiation. Light source; Scheme of the stigmatic SX700 monochromator; Resolution measurements.

  • Computer control of the SRC high-resolution beamline. Eisert, David E.; Bissen, Mark; Fisher, Mike V.; Reininger, Ruben; Stott, John P.; Hochst, Hartmut // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p1671 

    Discusses the complexities of controlling via computer the high-resolution soft x-ray beamline at the University of Wisconsin Synchrotron Radiation Center. Computer controls; Monochromator assembly; Rotational and translational motion; Calculation of positions; Software.

  • Plane-grating flat-field soft x-ray spectrometer. Hague, C. F.; Underwood, J. H.; Avila, A.; Delaunay, R.; Ringuenet, H.; Marsi, M.; Sacchi, M. // Review of Scientific Instruments;Feb2005, Vol. 76 Issue 2, p023110 

    We describe a soft x-ray spectrometer covering the 120–800 eV range. It is intended for resonant inelastic x-ray scattering experiments performed at third generation synchrotron radiation (SR) facilities and has been developed with SOLEIL, the future French national SR source in mind. The...

  • Ion processes in a liquid-xenon ionization chamber under high-intensity pulsed irradiation. Kirsanov, M. A.; Obodovskiy, I. M. // Instruments & Experimental Techniques;Mar2010, Vol. 53 Issue 2, p185 

    The current of positive ions in a liquid-xenon ionization chamber was studied under intense pulsed irradiation of the chamber with bremsstrahlung from a microtron. The dose absorbed in xenon during a radiation pulse was varied from 0.1 to 1.3 � 104 �Gy. It has been revealed that, in...

  • First spectral measurement of the Earth's upwelling emission using an uncooled wideband Fourier transform spectrometer. Palchetti, L.; Belotti, C.; Bianchini, G.; Castagnoli, F.; Carli, B.; Cortesi, U.; Pellegrini, M.; Camy-Peyret, C.; Jeseck, P.; Té, Y. // Atmospheric Chemistry & Physics Discussions;2006, Vol. 6 Issue 3, p4061 

    The first spectral measurement of Earth's emitted radiation to space in the wideband range from 100 to 1400 cm-1 with 0.5cm-1 spectral resolution is presented. The measurement was performed from a stratospheric balloon in tropical region using a Fourier transform spectrometer, during a field...

  • SPARTUVIX I1' An improved x-ray ultraviolet spectrograph with temporal and spatial capabilities for indirect drive inertial confinement fusion experiments (abstract) Bourgade, J. L.; Guilly, E.; Bruneau, J.; Gary, S.; Gontier, D.; Renaudin, P.; Reverdin, C.; Thiell, G.; Eldmann, K.; Winhart, G. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p1064 

    Describes the development of an improved version of the initial x-ray ultraviolet spectrograph SPARTUVIX to record the time evolution of spatially resolved spectra in the soft x-ray range. Applications of the diagnostic; Spatial resolution; Imaging system.

  • Twin-elliptical-crystal time- and space-resolved soft x-ray spectrometer. Lake, P. W.; Bailey, J. E.; Rochau, G. A.; Gard, P.; Petmecky, D.; Bump, M.; Joseph, N. R.; Moore, T. C.; Nielsen-Weber, L. B. // Review of Scientific Instruments;Oct2006, Vol. 77 Issue 10, p10F315 

    Elliptical crystal spectrometers equipped with time-gated microchannel plate (MCP) detectors provide time-, space-, and spectrally resolved data. A common problem is that the number of time resolution elements is limited by the number of MCP frames. The number of frames that fit on a given MCP...

  • Static multislit dispersive optical spectrometers for solid-state spectroscopy. Kuznetsov, A. V.; Martynovich, E. F. // Optics & Spectroscopy;Sep2008, Vol. 105 Issue 3, p478 

    Multislit entrance apertures and corresponding sequences of numbers, which are simpler and more efficient than available analogs, are proposed for application in static multislit dispersive optical spectroscopy. The use of reflective multislit entrance apertures based on the proposed sequences...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics