TITLE

Trace element determination in seawater by ICP-SFMS coupled with a microflow nebulization/desolvation system

AUTHOR(S)
Turetta, Clara; Cozzi, Giulio; Barbante, Carlo; Capodaglio, Gabriele; Cescon, Paolo
PUB. DATE
September 2004
SOURCE
Analytical & Bioanalytical Chemistry;Sep2004, Vol. 380 Issue 2, p258
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Direct and simultaneous determination of Al, Ag, As, Cd, Co, Cr, Cu, Fe, Mn, Mo, Pb, Sb, U, V and Zn in diluted (1:10 v:v) seawater from the Antarctic Ocean and the Venice Lagoon at the ng mL-1 and pg mL-1 level has been performed by using an inductively coupled plasma sector field mass spectrometer (ICP-SFMS). Samples were analysed by using a PFA microflow nebulizer coupled with a desolvation system or a PFA microflow nebulizer coupled with a Teflon spray chamber, respectively. Measurements were carried out at low (LR,m/?m=300), medium (MR,m/?m=3,000) and high (HR,m/?m=7,500) resolutions depending on the studied isotope. To avoid contamination, sample pre-treatment was carried out in a clean laboratory equipped with a Class 100 vertical laminar flow hood. Concentration ranges (minimum-maximum in ng mL-1) found in the Antarctic seawater samples (in depth profiles) were: Ag 0.0004-0.0018, As 0.69-1.32, Cd 0.031-0.096, Co 0.018-0.065, Cr 0.18-0.46, Cu 0.04-1.58, Fe 0.13-1.63, Mn 0.02-0.12, Mo 5.97-12.46, Pb 0.007-0.074, Sb 0.033-0.088, U 0.5-1.9, V 0.6-2.5 and Zn 0.16-0.80. Concentration ranges (min-max in ng mL-1) found in the Venice Lagoon water samples (temporal profile from a benthic chamber experiment) were: Al 0.24-0.61, Ag 0.007-0.031, As 1.42-2.27, Cd 0.050-0.182, Co 0.440-1.461, Cr 0.15-0.34, Cu 0.81-2.46, Fe 0.25-1.66, Mn 11.6-31.7, Mo 6.50-10.6, Pb 0.047-0.225, Sb 0.240-0.492, U 1.7-3.3, V 1.3-2.8 and Zn 5.20-21.5. The detection limits range between 0.06 pg mL-1 for Ag and U to 15 pg mL-1 for Fe. In order to check the accuracy of the analytical procedure, measurements of the trace elements in a certified reference material (coastal Atlantic seawater, CASS-4-NRCC) were compared with the certified values. In addition, the results from the Antarctic and Venice Lagoon samples were compared with those obtained by using different analytical techniques.
ACCESSION #
14665101

 

Related Articles

  • Variability of the phase function of atmospheric aerosols at large scattering angles. Kokhanovsky, A.A. // Journal of the Atmospheric Sciences;2/1/98, Vol. 55 Issue 3, p314 

    Studies the variability of phase functions of submicrometer atmospheric aerosols. Definition of the phase function of atmospheric aerosols; Results of the findings.

  • Recent Developments in LC-MS-MS for the Identification and Measurement of Nanoscale Amounts of Proteins and Peptides. Thomas, Robert // Spectroscopy;Jan2001, Vol. 16 Issue 1, p28 

    Presents information on the developments in liquid chromatography and mass spectrometers (MS) technology for the analysis of biomolecules. Description of several electrospray devices and components; Discussion of mass spectrometric detection; Benefit of the MS-MS design.

  • Non-equivalent water molecules in [Ni(H2O)6](ClO4)2 and in [Ni(D2O)6](ClO4)2 in the thermogravimetric investigations. Rachwalska, Malgorzata; Majda, Dorota // Journal of Thermal Analysis & Calorimetry;Jul2007, Vol. 89 Issue 1, p277 

    The thermal decomposition of [Ni(H2O)6](ClO4)2 and [Ni(D2O)6](ClO4)2 were studied by thermogravimetric analysis (TG) and simultaneous differential thermal analysis (SDTA) at a constant heating rate. The gaseous products of the decomposition were on-line identified by a quadrupole mass...

  • On aerosol direct shortwave forcing and the Henyey-Greenstein phase function. Boucher, Oliver // Journal of the Atmospheric Sciences;1/1/98, Vol. 55 Issue 1, p128 

    Discusses the importance of the Henyey-Greenstein phase function in determining aerosol forcing in the light of extensive computations of upscatter fractions. Comparison of realistic Mie phase functions to the corresponding Henyey-Greestein phase functions.

  • A Wind Tunnel Study of Turbulence Effects on the Scavenging of Aerosol Particles by Water Drops. Vohl, O.; Mitra, S.K.; Diehl, K.; Huber, G.; Wurzler, S.C.; Kratz, K.-L.; Pruppacher, H.R. // Journal of the Atmospheric Sciences;10/15/2001, Vol. 58 Issue 20, p3064 

    Examines the turbulence effect of water drops on the scavenging of aerosol particles. Suspension of drops on terminal velocities in the Mainz vertical wind tunnel for investigation; Involvement of turbulence on the collisions between aerosol particles and drops; Description of the wind tunnel...

  • An Evaluation of the Community Aerosol Inlet for the NCAR C-130 Research Aircraft. Blomquist, B.W.; Huebert, B.J.; Howell, S.G.; Litchy, M.R.; Twohy, C.H.; Schanot, A.; Baumgardner, D.; Laufleur, B.; Seebaugh, R.; Laucks, M.L. // Journal of Atmospheric & Oceanic Technology;Aug2001, Vol. 18 Issue 8, p1387 

    Presents a study which evaluated the Community Aerosol Inlet (CAI) in the National Center for Atmospheric Research (NCAR). Factors known to contribute to inlet losses; Development of the CAI on the NCAR C-130 research aircraft; Velocity and turbulence measurements; Modeled flow and transmission...

  • Closure between measured and modeled cloud condensation nuclei (CCN) using size-resolved aerosol compositions in downtown Toronto. Broekhuizen, K.; Chang, R.Y.-W.; Leaitch, W. R.; Li, S.-M.; Abbatt, J. P. D. // Atmospheric Chemistry & Physics;2006, Vol. 6 Issue 9, p2513 

    Measurements of cloud condensation nuclei (CCN) were made in downtown Toronto during August and September, 2003. CCN measurements were performed at 0.58% supersaturation using a thermal-gradient diffusion chamber, whereas the aerosol size distribution and composition were simultaneously measured...

  • Chemically-resolved aerosol volatility measurements from two megacity field studies. Huffman, J. A.; Docherty, K. S.; Aiken, A. C.; Cubison, M. J.; Ulbrich, I. M.; DeCarlo, P. F.; Sueper, D.; Jayne, J. T.; Worsnop, D. R.; Ziemann, P. J.; Jimenez, J. L. // Atmospheric Chemistry & Physics;2009 Part 2 of 2, Vol. 9 Issue 18, p7161 

    The volatilities of different chemical species in ambient aerosols are important but remain poorly characterized. The coupling of a recently developed rapid temperature-stepping thermodenuder (TD, operated in the range 54-230°C) with a High-Resolution Time-of-Flight Aerosol Mass Spectrometer...

  • Source apportionment of submicron organic aerosols at an urban site by factor analytical modelling of aerosol mass spectra. Lanz, V. A.; Alfarra, M. R.; Baltensperger, U.; Buchmann, B.; Hueglin, C.; Prévôt, A. S. H. // Atmospheric Chemistry & Physics;2007, Vol. 7 Issue 6, p1503 

    Submicron ambient aerosol was characterized in summer 2005 at an urban background site in Zurich, Switzerland, during a three-week measurement campaign. Highly time-resolved samples of non-refractory aerosol components were analyzed with an Aerodyne aerosol mass spectrometer (AMS). Positive...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics