TITLE

Comprehensive analysis of the spectrometric determination of voltage applied to X-ray tubes in the radiography and mammography energy ranges using a silicon PIN photodiode

AUTHOR(S)
Terini, R. A.; Pereira, M. A. G.; Künzel, R.; Costa, P. R.; Herdade, S. B.
PUB. DATE
May 2004
SOURCE
British Journal of Radiology;May2004, Vol. 77 Issue 917, p395
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
This work describes the analysis of factors which affect the results of estimation of the electron accelerating potential (kVp) applied to an X-ray tube, through determination of the end point of the energy spectrum of the emitted radiation beam. Measurements have been performed utilizing two spectrometers each with a silicon PIN photodiode: one operating at room temperature, and the other, a high resolution spectrometer, with a Peltier cooler. Both were directly irradiated by different X-ray beams. Both systems work at low voltage and without liquid nitrogen cooling, thus avoiding the drawbacks presented by germanium detectors. Each kVp value was determined by linear regression of the end of the spectrum, so as to give, simultaneously, the best fit to the experimental data and low standard deviation for the kVp value. Detector energy resolution and calibration, counting statistics and high voltage waveform ripple have been investigated in order to establish better experimental conditions and to optimize measurement time. Results of measurements carried out with X-ray tubes connected to single-phase, three-phase or constant potential units, using additional filtration of Cu, Al or Mo (for mammographic beams), are presented. The variations resulted in kVp uncertainties up to 0.1 kV.
ACCESSION #
14593984

 

Related Articles

  • THE DETECTION OF COLONIC LESIONS BY DOUBLE CONTRAST AND HIGH VOLTAGE RADIOGRAPHY. Crozier, Henry C. // American Journal of Gastroenterology;Feb1954, Vol. 21 Issue 2, p137 

    Details the detection of colonic lesions by double contrast and high voltage radiography. Case study of a patient with a history of bleeding with a negative sigmoidoscopic examination; Analysis of the roentgenograms of the patients; Indications for a double study.

  • Considerations on the measurement of practical peak voltage in diagnostic radiology. Ram''rez-Jim''nez F J; L''pez-Callejas R; Ben''tez-Read J S; Pacheco-Sotelo J O // British Journal of Radiology;Sep2004, Vol. 77 Issue 921, p745 

    An evaluation of the non-invasive measurement of the practical peak voltage (PPV) in the quality control of X-ray units used in diagnostic radiology was carried out. Two instruments were employed: the PTW Diavolt Universal Tester with readings in PPV and the Waveform Tester for X-rays (WATEX)...

  • Results of mass testing of mini drift tubes for the D0 forward muon system. Abazov, V.; Alekseev, G.; Baranov, V.; Vetrogradov, L.; Zhuravlev, N.; Kalinin, A.; Kalinnikov, V.; Komissarov, E.; Kravchuk, N.; Kuchinskii, N.; Malyshev, V.; Merekov, Yu.; Merzlyakov, S.; Moiseenko, A.; Nozdrin, A.; Porokhovoi, S.; Prokhorov, I.; Sabirov, B.; Stakhin, A.; Tokmenin, V. // Instruments & Experimental Techniques;Jan2007, Vol. 50 Issue 1, p51 

    The procedures and results of mass testing of mini drift tubes in the course of their production for the D0 forward muon system (Tevatron, Fermilab) are described. High-voltage training, checking the stability and uniformity of signals induced by X rays, measuring the wire tension, and leak...

  • Monte Carlo simulations of microchannel plate detectors. II. Pulsed voltage results. Kruschwitz, Craig A.; Wu, Ming; Rochau, Greg A. // Review of Scientific Instruments;Feb2011, Vol. 82 Issue 2, p023102 

    This paper is the second part of a continuing study of straight-channel microchannel plate (MCP)-based x-ray detectors. Such detectors are a useful diagnostic tool for two-dimensional, time-resolved imaging and time-resolved x-ray spectroscopy. To interpret the data from such detectors, it is...

  • IS DIGITAL BETTER IN DENTAL RADIOGRAPHY? Zdešar, U.; Fortuna, T.; Valantië, B.; Šrk, D. // Radiation Protection Dosimetry;2008 Special Issue, Vol. 129 Issue 1-3, p138 

    In Slovenia, dental radiography was the first field in which projection x-ray imaging using digital detectors was done. At present around 30% of intraoral dental x-ray units use digital detectors. Annual test results were analysed to compare digital systems with film-based ones. The survey...

  • Imaging Using Energy Discriminating Radiation Detector Array. Willson, Paul D.; Clajus, Martin; Tümer, Tümay O.; Visser, Gerard; Cajipe, Victoria // AIP Conference Proceedings;2003, Vol. 680 Issue 1, p913 

    Industrial X-ray radiography is often done using a broad band energy source and always a broad band energy detector. There exist several major advantages in the use of narrow band sources and or detectors, one of which is the separation of scattered radiation from primary radiation. ARDEC has...

  • An X-ray Diffractometer with a Mobile Emitter-Detector System. Asadchikov, V.; Babak, V.; Buzmakov, A.; Dorokhin, Yu.; Glagolev, I.; Zanevskii, Yu.; Zryuev, V.; Krivonosov, Yu.; Mamich, V.; Moseiko, L.; Moseiko, N.; Mchedlishvili, B.; Savel’ev, S.; Senin, R.; Smykov, L.; Tudosi, G.; Fateev, V.; Chernenko, S.; Cheremukhina, G.; Cheremukhin, E. // Instruments & Experimental Techniques;May/Jun2005, Vol. 48 Issue 3, p364 

    An X-ray diffractometer with a mobile emitter-detector system is able to perform various X-ray examinations of a stationary sample. The design for this instrument is described, along with its operating principles and control programs. Owing to its high-precision angular movement sensors and its...

  • Two-dimensional Detector for High Resolution Soft X-ray Imaging. Ejima, Takeo; Ogasawara, Shodo; Hatano, Tadashi; Yanagihara, Mihiro; Yamamoto, Masaki // AIP Conference Proceedings;6/24/2010, Vol. 1234 Issue 1, p811 

    A new two-dimensional (2D) detector for detecting soft X-ray (SX) images was developed. The detector has a scintillator plate to convert a SX image into a visible (VI) one, and a relay optics to magnify and detect the converted VI image. In advance of the fabrication of the detector, quantum...

  • Microcontrolled pyro-electric instrument for measuring X-ray intensity in mammography. De Paula, M. H.; De Carvalho, A. A.; Brassalotti, A. L.; Alter, A. J.; Sakamoto, W. K.; Malmonge, J. A.; De Almeida, A. // Medical & Biological Engineering & Computing;Nov2005, Vol. 43 Issue 6, p751 

    A novel instrument for measurement of X-ray intensity from mammography consists of a sensitive pyro-electric detector, a high-sensitivity, low-noise current-to-voltage converter, a microcontroller and a digital display. The heart of this device, and what makes it unique is the pyro-electric...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics