TITLE

Dosimetric comparison between three- and four-dimensional computerised tomography radiotherapy for breast cancer

AUTHOR(S)
Yan, Yanli; Lu, Zhou; Liu, Zi; Luo, Wei; Shao, Shuai; Tan, Li; Ma, Xiaowei; Liu, Jiaxin; Drokow, Emmanuel Kwateng; Ren, Juan
PUB. DATE
August 2019
SOURCE
Oncology Letters;Aug2019, Vol. 18 Issue 2, p1800
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
At present, methods of radiotherapy simulation for breast cancer based on four-dimensional computerised tomography (4D-CT) or three-dimensional CT (3D-CT) simulation remain controversial. In the present study, 7 patients with residual breast tissue received whole breast radiotherapy based on 3D-CT and 4D-CT simulation. For the 4D-CT plan, four types of CT images were produced, including images of the end of inspiration and the end of expiration, and images acquired by the maximal intensity projection (MIP) and average intensity projection (AIP). In the 3D-CT plan, the clinical target volume (CTV) and plan target volume (PTV) were marginally higher compared with the 4D-CT plan. In addition, the minimum point dose of the target volume (Dmin), the maximum point dose of the target volume (Dmax) and the mean point dose of the target volume (Dmean) of the CTV and PTV in the MIP and AIP plans were marginally higher compared with the 3D-CT plan. For the contralateral breast (C-B), volumes of the 4D-CT plan were markedly lower compared with the 3D-CT plan. Furthermore, Dmin, Dmax and Dmean of the 3D-CT plan were higher compared with the AIP and MIP plans. For the ipsilateral lungs (I-L), volumes of the 3D-CT and AIP plans were higher compared with the MIP plan. Furthermore, when breast lesions were on the left side, for the heart, the volume receiving no less than 40% of the prescription dose (V40) and the volume receiving no less than 30% of the prescription dose (V30) of the MIP and AIP plans were slightly lower compared with those of the 3D plan. In conclusion, 4D-CT radiotherapy based on the MIP and AIP plans provides a slightly smaller radiation area and slightly higher radiotherapy dosage of the CTV and PTV compared with 3D-CT radiotherapy for breast radiotherapy. Therefore, the MIP and AIP plans prevent C-B radiation exposure and improve sparing of the heart and I-L.
ACCESSION #
137415542

 

Related Articles

  • Radiation dosimetry Cameron, J. // Environmental Health Perspectives;Feb1991, Vol. 91, p45 

    No abstract available.

  • Orbital Therapy gets U.S. patent for new breast cancer treatment.  // Medical Device Daily;5/19/2009, Vol. 13 Issue 95, p3 

    The article reports on the U.S. patent issued to Orbital Therapy for a unique external beam radiotherapy treatment machine optimized for breast cancer patients. The device will allow the clinician to have full access to the breast and will protect the patient from unwanted exposure to radiation....

  • Impact of different breathing conditions on the dose to surrounding normal structures in tangential field breast radiotherapy. Prabhakar, Ramachandran; Tharmar, Ganesh; Julka, Pramod K.; Rath, Goura K.; Joshi, Rakesh C.; Bansal, Anil K.; Bischt, R. K.; Gopishankar, N.; Pant, G. S.; Thulkar, S. // Journal of Medical Physics;Jan-Mar2007, Vol. 32 Issue 1, p24 

    Cardiac toxicity is an important concern in tangential field breast radiotherapy. In this study, the impact of three different breathing conditions on the dose to surrounding normal structures such as heart, ipsilateral lung, liver and contralateral breast has been assessed. Thirteen patients...

  • Dural Metastasis From Breast Carcinoma Mimicking Subdural Hematoma: Case Report. OKTAY, Kadir; ÖZSOY, Kerem Mazhar; ÇETİNALP, Nuri Eralp; GEZERCAN, Yurdal; OLGUNER, Semih Kıvanç; SARAÇ, Mustafa Emre // Journal of Neurological Sciences;2014, Vol. 31 Issue 4, p818 

    While intracerebral metastases are common, insulated dural metastases are seen very rarely. The clinical and radiological features of this uncommon condition are often unsuspected and could mimic various benign conditions such as meningioma and subdural hematoma (SDH) as reported in the...

  • Perspectives on radiation dose in abdominal imaging. Cook, Tessa S.; Hilton, Susan; Papanicolaou, Nicholas // Abdominal Imaging;Dec2013, Vol. 38 Issue 6, p1190 

    Reported instances of patients’ overexposure to imaging-related radiation have spurred the radiology and medical physics communities to identify and develop methods for decreasing the amount of radiation used to achieve diagnostic-quality images. These initiatives include examining and...

  • Target volume delineation in breast conserving radiotherapy: are co-registered CT and MR images of added value? Mast, Mirjam; Coerkamp, Emile; Heijenbrok, Mark; Scholten, Astrid; Jansen, Wim; Kouwenhoven, Erik; Nijkamp, Jasper; de Waard, Stephanie; Petoukhova, Anna; Struikmans, Henk // Radiation Oncology;2014, Vol. 9 Issue 1, p1 

    Introduction In breast conserving radiotherapy differences of target volume delineations between observers do occur. We evaluated whether delineations based on co-registered computed tomography (CT) and magnetic resonance (MR) imaging may result in an improved consistency between observers. We...

  • New Breast Cancer Treatment.  // Medical Update;Jul2002, Vol. 28 Issue 1, p7 

    Provides information on the MammoSite Radiation Therapy System for breast cancer.

  • MEDICAL RADIATION AND TODAY'S BREAST CANCER EPIDEMIC. Faloon, William // Life Extension;Aug2010, Vol. 16 Issue 8, p5 

    In this article the author discusses physical problems such as breast cancer which have allegedly been linked to exposure to radiation in the medical setting including radiation from computed tomography (CT) scans. He is critical of what he calls the overuse of CT scans but argues that despite...

  • ON THE ESTIMATION OF RADIATION-INDUCED CANCER RISKS FROM VERY LOW DOSES OF RADIATION AND HOW TO COMMUNICATE THESE RISKS. Mattsson, Sören; Nilsson, Mats // Radiation Protection Dosimetry;2015 Special Issue, Vol. 165, p17 

    The article is intended to give a short overview of epidemiological data on cancer risks associated with very low absorbed doses of ionising radiation. The linear no-threshold (LNT) approach to estimate cancer risks involves the use of epidemiological data at higher doses (>100 mSv), but is...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics