TITLE

Improved hydrodynamics of a new aortic cannula with a novel tip design

AUTHOR(S)
Scharfschwerdt, Michael; Richter, Axel; Boehmer, Kurt; Repenning, Detlef; Sievers, Hans-H.
PUB. DATE
May 2004
SOURCE
Perfusion;May2004, Vol. 19 Issue 3, p193
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: Reduction of atheroembolic complications during cardiopulmonary bypass remains a major challenge in cardiac surgery. New cannula tip designs may help to attenuate this problem by improved hydrodynamics. Methods: Pressure gradients and back pressures of a new aortic cannula tip design were measured and compared with the Medos X-Flow, Sarns Soft-Flow and Argyle THI cannulae at various flow rates in a mock circulation followed by flow visualization. Results: Pressure gradients were the lowest for the new cannula. Back pressures of the new cannula were up to 84% lower than for the Argyle cannula. The back pressure profile and flow visualization of the new cannula showed broad centric flow dispersion with a transcannula increase of flow area from 38 mm2 to 139 mm2. Conclusions: The new design of an aortic cannula tip provides improved hydrodynamics, with low pressure gradients, low back pressures and a uniform central dispersion of flow, reducing the sandblasting effect.
ACCESSION #
13610746

 

Related Articles

  • Liver blood flow during cardiac surgery. Chetty, Govind; Sharpe, David A.C.; Nandi, Jay; Butler, Stephen J.; Mitchell, Ian M. // Perfusion;May2004, Vol. 19 Issue 3, p153 

    Objective: Impairment of liver blood flow and, therefore, potentially liver function, has important short-term consequences because of the liver's key metabolic importance and role in drug metabolism. The objective of this study was to quantify the effect of cardiac surgery on liver blood flow...

  • Systemic arterial waveform analysis and assessment of blood flow during extracorporeal circulation. Romano, Salvatore M.; Scolletta, Sabino; Olivotto, Iacopo; Biagioli, Bonizella; Gensini, Gian Franco; Chiostri, Marco; Giomarelli, Pierpaolo // Perfusion;Mar2006, Vol. 21 Issue 2, p109 

    Background: The pressure recording analytical method (PRAM) is a method for real-time beat-to-beat quantification of peripheral blood flow based on the analysis of arterial waveform morphology. Since PRAM can be implemented in any conditions of flow, whether physiological or artificial, we...

  • Coronary Revascularization in Adults with Dextrocardia. Murtuza, Bari; Gupta, Prity; Goli, Giri; Lall, Kulvinder S. // Texas Heart Institute Journal;2010, Vol. 37 Issue 6, p633 

    Most reports of coronary artery bypass grafting in adult patients with dextrocardia have focused on the surgeon's position with respect to the operating table. Herein, we describe the cases of 2 patients with dextrocardia who underwent surgery at our own institution, then discuss preoperative...

  • Use of warm priming solution in open heart surgery: its effects on hemodynamics and acute inflammation. Buyukates, M.; Acikgoz, S.; Kandemir, O.; Aktunc, E.; Ceylan, E.; Can, M. // Perfusion;Mar2008, Vol. 23 Issue 2, p89 

    Cardiac surgery causes an acute inflammatory response and organ damage. In this study, for the first time in the literature, we compared the effects of priming solutions at 20°C and 36°C on acute inflammatory markers and hemodynamic parameters. Forty patients were recruited and randomized...

  • Validation of cardiac output monitoring based on uncalibrated pulse contour analysis vs transpulmonary thermodilution during off-pump coronary artery bypass grafting. Smetkin, A. A.; Hussain, A.; Kuzkov, V. V.; Bjertnæs, L. J.; Kirov, M. Y. // BJA: The British Journal of Anaesthesia;Jun2014, Vol. 112 Issue 6, p1024 

    Background Cardiac output monitoring, as a part of a goal-directed haemodynamic management, has been shown to improve perioperative outcome in high-risk patients undergoing major surgical interventions. However, thorough validation of cardiac output monitoring devices in different clinical...

  • Long-term digital blood flow after radial artery harvesting for coronary artery bypass grafting Lee, Hyun-Sung; Heo, Youn Jeong; Chang, Byung-Chul // European Journal of Cardio-Thoracic Surgery;Jan2005, Vol. 27 Issue 1, p99 

    Abstract: Objective: The radial artery is widely used as a bypass conduit in coronary artery bypass surgery, but the long-term flow readjustment in the hands and fingers induced by the removal of the radial artery is poorly understood. Methods: Using pulse-volume-recording plethysmography,...

  • Analysis of thoracic aortic blood flow during off-pump coronary artery bypass surgery. Decoene, Christophe; Modine, Thomas; Al-Ruzzeh, Sharif; Athanasiou, Thanos; Fawzi, Dina; Azzaoui, Richard; Pol, Annie; Fayad, Georges // European Journal of Cardio-Thoracic Surgery;Jan2004, Vol. 25 Issue 1, p26 

    Objectives: The non-invasive monitoring of thoracic aortic blood flow (TABF) during off-pump coronary artery bypass (OPCAB) surgery is becoming more commonly used and proved to be invaluable in the early detection of haemodynamic compromise due to heart displacement. The aim of this study was to...

  • New technique of local ischemic preconditioning induction without repetitive aortic cross-clamping in cardiac surgery. Kurapeev, Dmitry I.; Kabanov, Viktor O.; Grebennik, Vadim K.; Sheshurina, Tatyana A.; Dorofeykov, Vladimir V.; Galagudza, Michael M.; Shlyakhto, Eugene V. // Journal of Cardiothoracic Surgery;2015, Vol. 10 Issue 1, p71 

    Background Several studies have demonstrated that local ischemic preconditioning can reduce myocardial ischemia-reperfusion injury in cardiac surgery patients; however, preconditioning has not become a standard cardioprotective intervention, primarily because of the increased risk of...

  • A novel composite coronary bypass graft strategy: the saphenous vein bridge—a pilot study. Tremblay, Jan-Alexis; Stevens, Louis-Mathieu; Chartrand-Lefebvre, Carl; Chandonnet, Martin; Mansour, Samer; Soulez, Gilles; Prieto, Ignacio; Basile, Fadi; Noiseux, Nicolas // European Journal of Cardio-Thoracic Surgery;Oct2013, Vol. 44 Issue 4, pe302 

    OBJECTIVES The aim of this pilot study was to describe and assess the safety of a novel composite graft technique for coronary artery bypass grafting (CABG) surgery. A saphenous vein is grafted to the left anterior descending artery (LAD) and other anterolateral coronary arteries, creating a...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library