TITLE

Status of the Trasco Intense Proton Source and emittance measurements

AUTHOR(S)
Celona, L.; Ciavola, G.; Gammino, S.; Chines, F.; Presti, M.; Andò, L.; Guo, X. H.; Gobin, R.; Ferdinand, R.
PUB. DATE
May 2004
SOURCE
Review of Scientific Instruments;May2004, Vol. 75 Issue 5, p1423
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The Trasco Intense Proton Source (TRIPS) was installed at INFN-LNS in May 2000 and has been fully operational since the Fall of 2000; now the source fulfills all the requirements of the TRASCO (Trasmutazione Scorie) project. The proton beam intensity easily exceeds 40 mA at the operating voltage of 80 kV. A set of emittance measurements was carried out for different source conditions and confirmed the simulations performed with the AXCEL code: in all the cases the rms normalized emittance is well lower than the value required for the injection into the RFQ (0.2 π mm mrad); the results will be shown and discussed. Finally a beam reliability of 99.8% has been found during a long run test lasting over 142 h. © 2004 American Institute of Physics.
ACCESSION #
13154607

 

Related Articles

  • Improvement of beam emittance of the CEA high intensity proton source SILHI. Gobin, R.; Beauvais, P.-Y.; Ferdinand, R.; Leroy, P.-A.; Celona, L.; Ciavola, G.; Gammino, S. // Review of Scientific Instruments;Jun99, Vol. 70 Issue 6, p2652 

    Discusses the improvement of beam emittance of the Commisariat a l'Energie Atomique high intensity proton source SILHI. Beam emittance measurements.

  • Beam diagnostic techniques for a small-size high-efficiency radio-frequency ion source. Zakhary, S.G. // Review of Scientific Instruments;Dec1995, Vol. 66 Issue 12, p5419 

    Describes a technique for measuring important parameters to evaluate small-size high-efficiency radio-frequency ion source. Beam emittance of the ion source; Energy spread; Charge spectra; Total extracted ion current; Beak emittance.

  • Sectional and projectional emittance measurements (abtract)[sub a)]. Sarstedt, M. // Review of Scientific Instruments;Mar96, Vol. 67 Issue 3, p1271 

    Discusses an abstract about sectional and projectional emittance measurements. Ion sources; Determining parameters for beam quality; Observation of clear aberrative distortions of the emittance during projection of the four-dimensional space onto a two-dimensional plane.

  • A high-current microwave ion source with permanent magnet and its beam emittance measurement. Yao, Zeen; Tan, Xinjian; Du, Hongxin; Luo, Ben; Liu, Zhanwen // Review of Scientific Instruments;Jul2008, Vol. 79 Issue 7, p073304 

    The progress of a 2.45 GHz high-current microwave ion source with permanent magnet for T(d,n)4He reaction neutron generator is reported in this paper. At 600 W microwave power and 22 kV extraction voltage, 90 mA peak hydrogen ion beam is extracted from a single aperture of 6 mm diameter. The...

  • Further development for the TRIUMF H[sup -]/D[sup -] multicusp source. Kuo, T.; Baartman, R.; Stevenson, N.; Dutto, G.; Schmor, P.; Gelbart, W. Z.; McDonald, M.; Yuan, D.; Jayamanna, K. // Review of Scientific Instruments;Feb1998, Vol. 69 Issue 2, p959 

    Examines the negative hydrogen/deuterium (H/D) multicusp source in Vancouver, British Columbia. Effect of the gas flow and neutralization on the operation of the source; Differences in the normalized emittance between negative D and H beams; Dependence of the negative D beam current on the...

  • Results and analysis of measurements on a proton-source beam for halo formation studies. Beauvais, P.-Y.; Chamouard, P.-A.; Ferdinand, R.; Haouat, G.; Lagniel, J.-M.; Pichoff, N.; Ruiz, C. // Review of Scientific Instruments;Mar96, Vol. 67 Issue 3, p1252 

    Reports on the detection and formation of halos developed by an intense proton beam in a long magnetic quadrupole FODO channel. Emittance measurement systems; Ratio of ion species; Percent observed increase emittance for a variation of the pressure by a factor of 2; Energy intensity of proton...

  • Numerical study of a linear accelerator using laser-generated proton beams as a source. Antici, P.; Fazi, M.; Lombardi, A.; Migliorati, M.; Palumbo, L.; Audebert, P.; Fuchs, J. // Journal of Applied Physics;Dec2008, Vol. 104 Issue 12, p124901 

    The injection of laser-generated protons through conventional drift tube linear accelerators (linacs) has been studied numerically. For this, we used the parameters of the proton source produced by ultraintense lasers, i.e., with an intrinsic high beam quality. The numerical particle tracing...

  • Physics Results from the Los Alamos Beam-Halo Experiment. Wangler, Thomas P. // AIP Conference Proceedings;2003, Vol. 693 Issue 1, p108 

    We present physics results from an experimental study of beam halo in a high-current 6.7-MeV proton beam propagating through a 52-quadrupole periodic-focusing channel. The gradients of the first four quadrupoles were independently adjusted to match or mismatch the injected beam. Emittances and...

  • Proton Synchrotron Radiation Diagnostics at HERA. Kube, G.; Priebe, G.; Wiebers, Ch.; Wittenburg, K. // AIP Conference Proceedings;2006, Vol. 868 Issue 1, p374 

    At HERA a proton synchrotron radiation beam emittance monitor has been installed which utilizes the radiation produced in the fringe field of a vertical deflecting dipole magnet. The beam spot is imaged onto the chip of a standard CCD camera by means of a concave mirror. An interference filter...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics