ABSTRACT
Objective: Current prosthetic heart valves necessitate permanent anticoagulation or have limited durability and impaired hemodynamic performance compared to natural valves. Recently a polymeric valve prostheses with special design for mitral position demonstrated excellent in vitro and in vivo results with improved durability and no need for permanent anticoagulation. In this study, a respective flexible polymeric aortic valve is presented and in vitro and in vivo results are reported. Methods: The aortic prosthesis (ADIAM® lifescience AG, Erkelenz, Germany) is entirely made of polycarbonaturethane. The tri-leaflet flexible prosthesis mimicks the natural aortic valve and has a diminished pressure loss and reduced stress and strain peaks at the commissures. The valve underwent long-term in vitro testing and in vivo-testing in a growing calve animal model (20 weeks, 7 aortic valves) and was compared to two different commercial bioprostheses. Results: The polymeric aortic heart valve substitute demonstrated excellent in vitro and in vivo hemodynamics. Five/seven animals with aortic PCU-prostheses had an excellent clinical long-term course. The explanted valves showed a variable degree of calcification. Two of the seven animals died at 27 and 77 days due to pannus overgrowth causing severe LVOTO without degeneration of the valve itself. Both animals with commercial bioprostheses had to be sacrificed because of congestive heart failure related to structural degeneration of the bioprosthesis after 10 and 30 days of implantation. There was no increased thrombogenity of the PCU valves compared to bioprostheses. Conclusion: The new flexible polymeric aortic valve prosthesis is superior to current bioprostheses in animal testing.
ACCESSION #
13115571

 

Related Articles

  • A technique for the fabrication of a more retentive nasal prosthesis. Gelareh Asadi; Ali Mirfazaelian; Amir A. Mangoli // Journal of Indian Prosthodontic Society;Jan2009, Vol. 9 Issue 1, p36 

    Retention is one of the most important considerations in fabricating a successful facial prosthesis. This article presents a technique using two acrylic resin extensions to provide more retention for a nasal prosthesis.

  • Non-rigid connectors in fixed prosthodontics: current concepts with a case report. Badwaik, P. V.; Pakhan, A. J. // Journal of Indian Prosthodontic Society;Jun2005, Vol. 5 Issue 2, p99 

    The occlusal forces applied to a fixed partial denture (FPD) are transmitted to the supporting structures through the pontic, connectors, and retainers. Variables that may influence the longevity of an FPD and its abutment include occlusion, span length, bone loss, and quality of periodontium....

  • Comparative Evaluation of Chewing Function with Removable Partial Dentures and Fixed Prostheses Supported by the Single-Crystal Sapphire Implant in the Kennedy Class II Partially Edentulous Mandible. Akagawa, Yasumasa; Okane, Hideaki; Kondo, Noriaki; Tsuga, Kazuhiro; Tsuru, Hiromichi // International Journal of Oral & Maxillofacial Implants;Fall1989, Vol. 4 Issue 3, p1 

    Differential chewing function with removable partial dentures (RPDs) and fixed prostheses supported by the single-crystal sapphire implant was evaluated in five subjects with Kennedy Class II partially edentulous mandibles by means of electromyography. Rehabilitation with the single-crystal...

  • Management of an unusual peripheral giant cell granuloma: A diagnostic dilemma. Mannem, Satheesh; Chava, Vijay K. // Contemporary Clinical Dentistry;Jan-Mar2012, Vol. 3 Issue 1, p93 

    The peripheral giant cell granuloma (PGCG) is a reactive exophytic lesion of the gingiva and alveolar ridge that usually occurs as a result of local irritating factors such as plaque, calculus, chronic infections, chronic irritation, tooth extraction, improperly finished fillings, unstable...

  • Upper limb function improvement following total elbow arthroplasty in patients with rheumatoid arthritis. Crook, Tim B.; Bissell, Iain J.; Barham, Guy S.; Hargreaves, David G. // European Journal of Orthopaedic Surgery & Traumatology;May2008, Vol. 18 Issue 4, p307 

    Thirty-one primary total elbow replacements were implanted in 25 patients with rheumatoid arthritis between 2000 and 2004 by a surgeon. Twenty-six implants were GSB III. Seven were Coonrad–Morrey prostheses. The mean age of the patients was 70 years (40–88); 18 women, 6 men. DASH...

  • Aortoventriculoplasty and left ventricle function: long-term follow-up. Sharma, Girish K.; Wojtalik, Michal; Siwińska, Aldona; Mroziński, Bartlomiej; Pawelec-Wojtalik, Malgorzata; Bartkowski, Rafal; Mrówczyński, Wojciech; Trojnarska, Olga // European Journal of Cardio-Thoracic Surgery;Jul2004, Vol. 26 Issue 1, p129 

    Objective: Depressed cardiac function after aortoventriculoplasty is well known during the postoperative period. Little data exist concerning the long-term follow-up. The aim of this study is to determine whether septal incision has any permanent effect on the left ventricle function. Methods:...

  • Leaflet arrest in St Jude Medical and CarboMedics valves: an experimental study. Grattan, Mark T.; Thulin, Lars I. // European Journal of Cardio-Thoracic Surgery;Jun2004, Vol. 25 Issue 6, p953 

    Objective: Two patients who suffered acute failure of their St Jude Medical Masters aortic valve prostheses due to leaflet arrest that were unrelated to suture material are presented. It was hypothesized that the valves failed because force applied to bear upon the valve annulus caused the hinge...

  • Uncemented STAR Total Ankle Prostheses. Anderson, Thomas; Montgomery, Fredrik; Carlsson, Âke // Journal of Bone & Joint Surgery, American Volume;Jul2003, Vol. 85-A Issue 7, p1321 

    Background: The feasibility of replacing the ankle joint has been a matter of speculation for a long time. In recent years, the designs of ankle prostheses have been improved, and three designs, all used without bone cement, currently dominate the market. However, documentation of the clinical...

  • Der Nasenbodenlift zur Verbesserung des Implantatlagers in der Oberkieferfront -- Klinische Erfahrungen der letzten 6 Jahre. GaggI, A.; Rainer, H.; Chiari, F. M. // Stomatologie;2004, Vol. 101 Issue 8, p191 

    Nasal floor elevation techniques in augmentative implant surgery of the anterior maxilla: clinical results. Nasal floor elevation techniques are seldom used in augmentative implant surgery of the anterior maxilla. In this study the main indication and clinical results of this augmentation...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics