TITLE

The effect of low force chiropractic adjustments on body surface electromagnetic field

AUTHOR(S)
John Zhang; Snyder, Brian J.; Vernor, Lori
PUB. DATE
March 2004
SOURCE
Journal of the Canadian Chiropractic Association;Mar2004, Vol. 48 Issue 1, p29
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Objective: The purpose of this study was to investigate the body surface electromagnetic field (EMF) changes using a sensitive magnetometer before and after a specific Toftness chiropractic adjustment in asymptomatic human subjects. Method: Forty-four subjects were randomly assigned into control (20 subjects) and experimental groups (24 subjects) in a pre and post-test design. The Triaxial Fluxgate Magnetometer FGM-5DTAA (Walker Scientific, Worcester Massachusetts) with five digit display and resolution of 1 nanotesla (nT) was used for EMF detection. The EMF in the research room and on the adjustment table was monitored and recorded. The subjects' body surface (cervical, thoracic, lumbar and sacral areas) EMF was determined in the prone position before and after the chiropractic adjustment. A low force Toftness chiropractic adjustment was applied to the cervical, thoracic, lumbar and sacral areas as determined by the practitioner Results: The EMF in the research room was recorded as 41611 nT at the Z axis (earth field), 13761 nTat the X axis and 7438 nT at the Yaxis. The EMF on the adjusting table changed minimally during the 15 minute observation period. The EMF on the subjects' body surface decreased at 4 spinal locations after chiropractic adjustment. The EMF (mean ± SD in nT) decreased significantly at the cervical region from 42449 ± 907 to 41643 ± 1165 (p < 0.01) and at the sacral regions from 43206 ± 760 to 42713 ± 552 (p <0.01). The EMF at the lumbar and thoracic regions decreased but did not reach a statistically significant level. No significant changes of the body surface EMF were found in the control group.
ACCESSION #
12949505

 

Related Articles

  • Lumbarisation of the First Sacral Vertebra a Rare Form of Lumbosacral Transitional Vertebra. Adibatti, Mallikarjun; Asha, K. // International Journal of Morphology;mar2015, Vol. 33 Issue 1, p48 

    In the lumbosacral region, anatomical variations occur with changes in the number of sacral vertebra either by deletion of first sacral vertebra or by the union of fifth lumbar or first coccygeal vertebra with sacrum. Lumbasacral transitional vertebrae (LSTV) is the most common congenital...

  • Lumbar perforator flap for closure of sacral tissue defect after lipomyelomeningocele. Dayicioglu, Deniz; Fan, Kenneth; Skowronski, Piotr; Kassira, Wrood; Thaller, Seth; Ercin, Burak; Levi, Allan // European Journal of Plastic Surgery;Mar2014, Vol. 37 Issue 3, p173 

    Complex sacral midline defects following spinal surgery have been traditionally closed with either muscle or musculocutaneous flaps. We present a case with a complicated sacral wound extending to the medulla spinalis after a lipomeningomyelocele excision in an ambulating adult. Wound was...

  • Preservation of the contralateral sacral nerves during hemisacrectomy for sacral malignancies. Li, Dasen; Guo, Wei; Tang, Xiaodong; Yang, Rongli; Tang, Shun; Qu, Huayi; Yang, Yi; Sun, Xin; Du, Zhiye // European Spine Journal;Sep2014, Vol. 23 Issue 9, p1933 

    Purpose: This study aimed to evaluate the oncologic and functional outcome of the cases treated with hemisacrectomy through a sagittal plane in the sacrum and simultaneous en bloc resection together with the ipsilateral sacroiliac joint without sacrificing the contralateral sacral nerves and...

  • Tunable high transition temperature superconducting quantum interference device magnetometer with gate-voltage-controlled bicrystal junctions. Kuen-Lin Chen; Sou, U. C.; Chen, J. C.; Yang, H. C.; Jeng, J. T.; Ko, P. C.; Horng, H. E.; Wu, C. H.; Chen, J. H. // Applied Physics Letters;7/20/2009, Vol. 95 Issue 3, p033504 

    A gate-voltage-controlled high transition temperature direct current superconducting quantum interference device (high-Tc dc SQUID) magnetometer was fabricated to study how the electric field effect affects the device’s voltage-flux and voltage-current characteristics. The magnetometer...

  • Flux dam, a method to reduce extra low frequency noise when a superconducting magnetometer is.... Koch, R.H.; Sun, J.Z. // Applied Physics Letters;7/31/1995, Vol. 67 Issue 5, p709 

    Examines the invention of the 'flux dam' and the effects of moderate magnetic field applied to a magnetometer. Analysis of the motion of trapped vortices in the zero field cooled case; Generation of low frequency flux noise due to thermal motion of trapped vortices; Operation of magnetometers...

  • Leg Pain in a Ball Player. Danchik, John J. // American Chiropractor;Jun2006, Vol. 28 Issue 6, p58 

    The article presents a case of an 18-year-old baseball player with aching pain and tightness in his left lower leg. Generally good alignment throughout the spine and pelvis, with normal spinal curves and no lateral curvature or listing is found after standing postural evaluation. Chiropractic...

  • Central lumbar disc prolapse following chiropractic manipulation: a call for audit of 'alternative practice'. Slater, R. N. S.; Spencer, J. D. // Journal of the Royal Society of Medicine;Oct1992, Vol. 85 Issue 10, p637 

    The article presents the case report of a 28-year-old woman with central lumbar disc prolapse after chiropractic manipulation. On examination, movements of the lumbar spine were found to be restricted and straight leg raising was limited by extreme nerve root tension. An emergency radiculogram...

  • Fractal analysis for the ULF data during the 1993 Guam earthquake to study prefracture criticality. Ida, Y.; Hayakawa, M. // Nonlinear Processes in Geophysics;2006, Vol. 13 Issue 4, p409 

    An extremely large earthquake (with magnitude of 8.2) happened on 8 August 1993 near the Guam island, and ultra-low-frequency (ULF) (frequency less than 1Hz) electromagnetic fields were measured by 3-axis induction magnetometers at an observing station (with the epicentral distance of 65 km)...

  • Low-pass filter in flux transformer circuits for SQUID magnetometers. Weyand, K. // Review of Scientific Instruments;Jun88, Vol. 59 Issue 6, p971 

    In order to eliminate extraneous alternating fields in magnetic field measuring setups using SQUID magnetometers, a compensating network has been developed which exhibits low-pass filter characteristics. Guidelines will be given for the optimal parameters of such circuits. On the basis of a...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics