The magnetic behavior of semiconducting EuSe islands deposited on a nanopatterned PbSe template is investigated using x-ray small-angle scattering and x-ray circular dichroism in absorption and scattering geometry. The islands form a regular hexagonal pattern, and show coupling between Eu spins at low temperatures, indicating a precursor state to a magnetic phase transformation. © 2004 American Institute of Physics.
ACCESSION #
12715435

 

Related Articles

  • A multichord soft x-ray diagnostic for electron temperature profile measurements in RFX-mod. Bonomo, F.; Franz, P.; Murari, A.; Gadani, G.; Alfier, A.; Pasqualotto, R. // Review of Scientific Instruments;Oct2006, Vol. 77 Issue 10, p10F313 

    We report on the design and first results obtained with a multichord diagnostic for the measurement of the electron temperature profiles in RFX-mod. The diagnostic consists of four groups of five photodiodes each, measuring the soft x-ray plasma emissivity through four pinholes. Each pinhole...

  • Duplex multiwire proportional x-ray detector for multichord time-resolved soft x-ray and electron temperature measurements on T-10 tokamak. Sushkov, A. V.; Andreev, V. F.; Kravtsov, D. E. // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10E319 

    Compact 64-channel multiwire proportional chamber is successfully used on T-10 and TCV tokamaks as a continuous-current soft x-ray detectors. The duplex multiwire proportional x-ray detector is a new generation of these detectors. It has been designed for simultaneous multichord measurement of...

  • Characterization of compact bright soft X-ray source based on picosecond laser plasma. Magunov, A. I.; Batani, D.; Faenov, A. Y.; Lucchini, G.; Desai, T.; Padoan, F.; Pikuz, T. A.; Skobelev, I. Y.; Canova, F.; Chiodini, N. // Applied Physics B: Lasers & Optics;Jan2006, Vol. 82 Issue 1, p19 

    Radiation emission of silicon and aluminum plasmas produced by 40-ps laser pulses with peak intensity above 1014 W/cm2 was studied. High-resolution soft X-rayspectra of H-like and He-like ions were analyzed to determine plasma parameters. We compared the line shape of resonance transitions and...

  • Quick X-ray reflectivity of spherical samples. Stoev, Krassimir; Sakurai, Kenji // Powder Diffraction;Jun2013, Vol. 28 Issue 2, p105 

    Recently, a new experimental setup for quick X-ray reflectivity (q-XRR) measurements was proposed, which is based on simultaneous recording of an X-ray reflectivity curve over all angles of interest. This new setup for q-XRR allows measurements to be done within seconds, thus permitting studies...

  • A simple spherical grating by-pass monochromator dedicated to soft x-ray emission spectroscopy Ghiringhelli, G.; Tagliaferri, A.; Braicovich, L.; Brookes, N. B. // Review of Scientific Instruments;Apr98, Vol. 69 Issue 4, p1610 

    Presents the spherical grating Polarized Light Improved Flux Efficiency Monochromator for soft x-ray emission spectroscopy. Description of the instrument; Analysis of the optical performance; Limiting factor of the device.

  • A slit grating spectrograph for quantitative soft x-ray spectroscopy. Wilhein, T.; Rehbein, S.; Hambach, D.; Berglund, M.; Rymell, L.; Hertz, H.M. // Review of Scientific Instruments;Mar99, Vol. 70 Issue 3, p1694 

    Describes a slit grating spectrograph for quantitative soft x-ray spectroscopy. Calibration of grating and charge coupled device (CCD); Measurement of absolute photon fluxes; Spectrograph's easy alignment and flexibility of use; Absolutely calibrated spectra obtained from a liquid-jet...

  • Modeling of a cylindrically expanding hydrogenlike fluorine x-ray laser. Eder, D. C. // Physics of Fluids B: Plasma Physics;Dec89, Vol. 1 Issue 12, p2462 

    Modeling results are presented for a hydrogenlike fluorine soft x-ray amplifier experiment performed at Rutherford Appleton Laboratory [Plasma Phys. Controlled Fusion 30, 35 (1988)] in which a gain coefficient of 4.4 cm-1 was observed. Simulations using various values of the flux limiter, f...

  • Erratum: A gas puff soft x-ray laser target design [J. Appl. Phys. 57, 971 (1985)]. Maxon, S.; Hagelstein, P.; Reed, K.; Scofield, J. // Journal of Applied Physics;8/15/1985, Vol. 58 Issue 4, p1706 

    Presents a correction to the article 'A Gas Puff Soft X-ray Laser Target Design,' which appeared in a 1985 issue of the 'Journal of Applied Physics.'

  • High-intensity flash x-ray apparatus for biomedical radiography. Sato, E.; Isobe, H.; Hoshino, F. // Review of Scientific Instruments;Jul1986, Vol. 57 Issue 7, p1399 