TITLE

디지털 제어장치의 고출력 전자기펄스에 대한 취약성 사례 분석

AUTHOR(S)
우정민; 주문노; 이홍식; 강성만; 최승규; 이재복
PUB. DATE
September 2017
SOURCE
Journal of Korean Institute of Electromagnetic Engineering & Sci;Sep2017, Vol. 28 Issue 9, p698
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The risk of high power electromagnetic(HPEM) pulse exposure to the devices used in digital control system such as PLC(programmable logic controller) and communication cable is increasing. In this paper, two different frequency ranges HPEMs were exposed to those control systems to assess the each vulnerability. The vulnerability of the EUTs exposed from HPEM were analyzed and compared with a variation of distances and source power. As the EUTs were exposed to higher level of HPEM, the voltage and communication waveform of the control system had shown a distorted response. And the unshielded twisted pair(UTP) cable connected to the EUTs showed operation failures with induced voltage. However, the foiled twisted pair(FTP) cable shielded the connected device efficiently from the HPEM exposure. Therefore, the necessity of the protection measures against the vulnerability of HPEM exposure for the digital control system used in power facilities and industrial site were verified.
ACCESSION #
125498820

 

Related Articles

  • Linear and nonlinear filters under high power microwave conditions. Brauer, F.; Ter Haseborg, J. L. // Advances in Radio Science;2009, Vol. 7, p255 

    The development of protection circuits against a variety of electromagnetic disturbances is important to assure the immunity of an electronic system. In this paper the behavior of linear and nonlinear filters is measured and simulated with high power microwave (HPM) signals to achieve a...

  • THERE'S NO SHORTAGE OF EW OPPORTUNITIES. Knowles, John // Journal of Electronic Defense;Jan2015, Vol. 38 Issue 1, p6 

    The article offers author's insights on the non shortage of electronic warfare (EW) opportunities. Topics mentioned include the 20th annivesary of the book "EW 101" by David Adamy and considering Adamy an asset to the EW community, the publishing of the first EW 101 article in the Journal of...

  • Full-Wave Analysis of Field-to-Line Coupling Effects Using 1D FDTD Method under Exciting Source with Different Bandwidths. Qi Zhang; Bihua Zhou; Jianbao Wang; Cheng Gao // Mathematical Problems in Engineering;2014, p1 

    With the aim to analyze field-to-line coupling effects based on energy spectrum, parallel finite-difference time-domain (FDTD) method is applied to calculate the induced voltage on overhead lines under high-power electromagnetic (HPEM) environment. Firstly, the energy distribution laws of HEMP...

  • Behavioral sequelae of exposure to higher power microwave fields. Akyel, Yahya // Current Psychology;Fall91, Vol. 10 Issue 3, p211 

    Focuses on behavioral patterns in rats caused by exposure to high peak power microwave pulses. Response failure in animals exposed to the microwaves; Impermanence of behavioral responses to microwave exposure; Duration of behavioral changes.

  • Sound generation in the atmosphere upon exposure to high-power milli- and microsecond laser pulses. Krasnenko, N. P.; Shamanaev, S. V.; Shamanaeva, L. G. // Russian Physics Journal;Sep2009, Vol. 52 Issue 9, p944 

    A review of works on generation of acoustic pulses in the atmosphere upon exposure to high-power laser pulses is presented in this paper. Characteristics of sound pulses in the atmosphere accompanying the propagation of high-power milli- and microsecond laser pulses, including the peak sound...

  • Double-clad fiber laser generates femtosecond pulses.  // Laser Focus World;Feb2002, Vol. 38 Issue 2, p13 

    Reports the development of a high-power, compact fiber laser that generates femtosecond pulses by researchers at the Universit é de Roeun and the Universit é d'Angers. Overview of the development process; Details of how the device works.

  • Quantifying and Minimizing Radiation Exposure During Pediatric Cardiac Catheterization. Campbell, R.M.; Strieper, M.J.; Frias, P.A.; Jeager, G.; Balfour, G.; Costello, L.; Sullivan, K.M. // Pediatric Cardiology;Jan/Feb2005, Vol. 26 Issue 1, p29 

    This study reports findings from evaluations of new technologies to measure radiation exposure during pediatric cardiac catheterization procedures. A strategy of pulsed fluoroscopy and low power settings resulted in significantly lower patient radiation exposure compared to conventional 60...

  • Power lines spark no extra risk, study says. Portner, Jessica // Education Week;07/09/97, Vol. 16 Issue 40, p10 

    Presents the results of a study conducted indicating that children who live near electric power lines have no greater risk of contracting leukemia than other children. Suggestions that high exposure heightens the risk of cancer and other illnesses; Gauging children's exposure to magnetic fields.

  • OS support for multimedia processor.  // Electronics Weekly;9/5/2007, Issue 2302, p31 

    The article evaluates an ultra high pulse load resistor type UXM 400 from Pulse Power Measurement.

  • A compact radiator of high-power electromagnetic pulses. Fortov, V.; Isaenkov, Yu.; Mikhailov, V.; Nesterov, E.; Ostashev, V.; Semenov, Yu.; Stroganov, V. // Journal of Communications Technology & Electronics;Nov2013, Vol. 58 Issue 11, p1065 

    The design and parameters of a compact radiator of high-power electromagnetic nanosecond pulses designed for simulation of ultra-wideband exposures in electromagnetic compatibility problems are described. It is shown that the effective pulse power of the radiator is 3 GW in the forward traveling...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics