TITLE

Accurate formulas for interaction force and energy in frequency modulation force spectroscopy

AUTHOR(S)
Sader, John E.; Jarvis, Suzanne P.
PUB. DATE
March 2004
SOURCE
Applied Physics Letters;3/8/2004, Vol. 84 Issue 10, p1801
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Frequency modulation atomic force microscopy utilizes the change in resonant frequency of a cantilever to detect variations in the interaction force between cantilever tip and sample. While a simple relation exists enabling the frequency shift to be determined for a given force law, the required complementary inverse relation does not exist for arbitrary oscillation amplitudes of the cantilever. In this letter we address this problem and present simple yet accurate formulas that enable the interaction force and energy to be determined directly from the measured frequency shift. These formulas are valid for any oscillation amplitude and interaction force, and are therefore of widespread applicability in frequency modulation dynamic force spectroscopy. © 2004 American Institute of Physics.
ACCESSION #
12405682

 

Related Articles

  • FTIR and FT-Raman Spectral Investigations on 4-Aminoquinaldine and 5-Aminoquinoline. Puviarasan, N.; Arjunan, V.; Mohan, S. // Turkish Journal of Chemistry;2004, Vol. 28 Issue 1, p53 

    The FTIR spectra of 4-aminoquinaldine and 5-aminoquinoline were recorded in solid phase on a Bruker IFS 66V spectrometer in the region 4000-400 cm-1. The FT-Raman spectra of these compounds were also recorded in the same instrument with a FRA 106 Raman module. The molecules under investigation...

  • Active atomic force microscopy cantilevers for imaging in liquids. Buguin, A.; Du Roure, O.; Silberzan, P. // Applied Physics Letters;5/7/2001, Vol. 78 Issue 19, p2982 

    We make an atomic force microscopy (AFM) cantilever oscillate by having an ac current circulating along it. When interacting with a permanent magnet, a normal force acts on the magnetic loop formed this way and induces its vibration. By choosing the current frequency at the resonance of the...

  • Accurate extraction method for the FM response of tunable diode lasers based on wavelength modulation spectroscopy. Chen, J.; Hangauer, A.; Strzoda, R.; Amann, M.-C. // Applied Physics B: Lasers & Optics;Feb2008, Vol. 90 Issue 2, p243 

    An accurate wavelength modulation spectroscopy based method to measure the dynamics of the wavelength modulation behavior of tunable diode lasers is introduced in this paper. This method requires only standard equipment and a simple mechanical setup. Under the condition of a constant laser...

  • Application of quantum cascade lasers to trace gas analysis. Kosterev, A.; Wysocki, G.; Bakhirkin, Y.; So, S.; Lewicki, R.; Fraser, M.; Tittel, F.; Curl, R. F. // Applied Physics B: Lasers & Optics;Feb2008, Vol. 90 Issue 2, p165 

    Quantum cascade (QC) lasers are virtually ideal mid-infrared sources for trace gas monitoring. They can be fabricated to operate at any of a very wide range of wavelengths from ∼ 3 μm to ∼ 24 μm. Seizing the opportunity presented by mid-infrared QC lasers, several groups...

  • Researcher measures resonant frequency of nanoscale cantilever.  // Electronics Weekly;4/11/2007, Issue 2283, p12 

    The article reports that researchers at Cornell University in Ithaca, New York has found a way to measure the resonant frequency of nanoscale cantilevers using an atomic force microscope (AFM). The researchers initially tap the cantilever with the AFM probe tip, then measure subsequent...

  • Capacity Optimization for Local and Cooperative Spectrum Sensing in Cognitive Radio Networks. El-Saleh, Ayman A.; Ismail, Mahamod; Ali, Mohd. A. M.; Alnuaimy, Ahmed N. H. // Proceedings of World Academy of Science: Engineering & Technolog;Feb2009 Supplement, Vol. 50, p69 

    The dynamic spectrum allocation solutions such as cognitive radio networks have been proposed as a key technology to exploit the frequency segments that are spectrally underutilized. Cognitive radio users work as secondary users who need to constantly and rapidly sense the presence of primary...

  • Oscillation-induced static deflection in scanning force microscopy. Heim, Lars-Oliver; Johannsmann, Diethelm // Review of Scientific Instruments;Jan2007, Vol. 78 Issue 1, p013902 

    Employing an atomic force microscope (AFM) in conjunction with a quartz crystal microbalance, we have investigated how a high-frequency lateral oscillation of the substrate influences the imaging process of the AFM. It was found that the time-averaged deflection of the cantilever (both vertical...

  • Signal amplitude and sensitivity of the Kelvin probe force microscopy. Ouisse, T.; Martins, F.; Stark, M.; Huant, S.; Chevrier, J. // Applied Physics Letters;1/23/2006, Vol. 88 Issue 4, p043102 

    When the tip-sample distance is small, Kelvin probe force microscopy is affected by parametric amplification. This is due to the fact that the electric force has two components; the higher one having a frequency exactly twice as high as the lower. The oscillation amplitude may substantially...

  • Combined normal and torsional mode in frequency-modulation atomic force microscopy for lateral dissipation measurement. Kunstmann, T.; Schlarb, A.; Fendrich, M.; Paulkowski, D.; Wagner, Th.; Möller, R. // Applied Physics Letters;4/10/2006, Vol. 88 Issue 15, p153112 

    We present a new method to measure lateral dissipation in frequency-modulation atomic force microscopy (FM-AFM). Conventional FM-AFM has been used to measure the topography. Additionally the cantilever has been excited in the first torsional mode, leading to a tip motion parallel to the surface....

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics