TITLE

Science commentary: Extracorporeal membrane oxygenation

AUTHOR(S)
Berger, Abi
PUB. DATE
October 1998
SOURCE
BMJ: British Medical Journal (International Edition);10/03/98, Vol. 317 Issue 7163, p916
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Focuses on the use of the extracorporeal membrane oxygenation technique which oxidized blood. Definition of extracorporeal membrane oxygenation; Number of extracorporeal membrane oxygenation centres in the United Kingdom; Insight into the use of the procedure on babies; Details on the benefits of the procedure to babies.
ACCESSION #
1223489

 

Related Articles

  • Identifying at Risk Infants Following Neonatal Extracorporeal Membrane Oxygenation. Kumar, Praveen; Shankaran, Seetha; Bedard, Mary P; Delaney-Black, Virginia // Journal of Perinatology;Jul99, Vol. 19 Issue 5, p367 

    OBJECTIVE: To identify infants at risk of death and abnormal neurodevelopmental outcome following extracorporeal membrane oxygenation (ECMO) in the neonatal period. METHODS: The medical records of 82 neonates treated with ECMO were reviewed to evaluate risk of death. All survivors were...

  • Extracorporeal membrane oxygenation saves lives. Boulton, Alison // BMJ: British Medical Journal (International Edition);7/20/96, Vol. 313 Issue 7050, p135 

    Reports on the use of extracorporeal membrane oxygenation for severely ill newborn babies. Cost of less invasive treatments; Decrease of risk of death from respiratory failure.

  • Hemodynamic troubleshooting for mechanical malfunction of the extracorporeal membrane oxygenation systems using the PPP triad of variables. Faulkner, Sherry C.; Johnson, Charles E.; Tucker, Juan L.; Schmitz, Michael L.; Fasules, James W.; Drummond-Webb, Jonathan J. // Perfusion;Sep2003, Vol. 18 Issue 5, p295 

    Prolonged usage of disposable extracorporeal membrane oxygenation (ECMO) circuitry increases the risk of mechanical complications due to breakdown or malposition of the circuit elements. Often, such complications are life threatening for the critically ill patient. Such problems need to be...

  • EXTRACORPOREAL MEMBRANE OXYGENATION.  // CONNECT: The World of Critical Care Nursing;2012, Vol. 9 Issue 1, p17 

    An abstract of the article "Extracorporeal Membrane Oxygenation," by Žiga Vrhovnik and Zoran Topić is presented.

  • Improved oxygenation with reduced recirculation during venovenous ECMO: comparison of two catheters. Rais-Bahrami, Khodayar; Walton, Dawn M.; Sell, Jeffrey E.; Rivera, Oswaldo; Mikesell, Gerald T.; Short, Billie L. // Perfusion;Nov2002, Vol. 17 Issue 6, p415 

    Objectives: To determine whether the new double-lumen catheter made by OriGen Biomedical (Austin, TX) for venovenous (VV) extracorporeal membrane oxygenation (ECMO) would reduce recirculation and improve oxygenation during VV ECMO when compared with the Kendall double-lumen catheter (Kendall...

  • The first succesful extracorporeal membranous oxygenation treatment in a child with refractory fulminant myocarditis in Turkey. Anıl, Ayşe Berna; Can, Fulya Kamit; Turhan, Soysal; Zengin, Neslihan; Anıl, Murat; Bakiler, Ali Rahmi; Doğrusöz, Buket // Anatolian Journal of Cardiology / Anadolu Kardiyoloji Dergisi;Dec2015, Vol. 15 Issue 12, p1036 

    A letter to the editor is presented in response to the article related to extracorporeal membranous oxygenation treatment of a pediatric patients presenting with acute fulminant myocarditis which was published in the previous issue of the periodical.

  • Portable Device Replaces Ventilator.  // USA Today Magazine;Feb2010, Vol. 138 Issue 2777, p14 

    The article reports on a new portable extracorporeal membrane oxygenation (ECMO) device, also known as an artificial lung, which oxygenates a patient's blood directly through a two-way connection via a single tube.

  • A paediatric ECMO case of plasma leakage through a polymethylpentene oxygenator. Gill, M. C.; O’Shaughnessy, K.; Dittmer, J. // Perfusion;Oct2015, Vol. 30 Issue 7, p600 

    Polymethylpentene (PMP) oxygenators, utilised for ECMO, are commonly believed to be resistant to plasma leakage. Whilst uncommon, plasma leakage has been previously reported with PMP fibres, both in vivo and in vitro. We describe a paediatric ECMO case during which plasma leakage occurred and...

  • Oseltamivir carboxylate accumulation in a patient treated by haemodiafiltration and extracorporeal membrane oxygenation. Lemaitre, Florian; Luyt, Charles-Edouard; Roullet-Renoleau, François; Nieszkowska, Ania; Zahr, Noël; Fernandez, Christine; Farinotti, Robert; Combes, Alain // Intensive Care Medicine;Jul2010, Vol. 36 Issue 7, p1273 

    A letter to the editor is presented related to accumulation of oseltamivir caroxylate in patients who are treated by extracorporeal membrane oxygenation and haemodiafiltration.

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics