TITLE

Practical electron-tunneling refrigerator

AUTHOR(S)
Clark, A. M.; Williams, A.; Ruggiero, S. T.; Van Den Berg, M. L.; Ullom, J. N.
PUB. DATE
January 2004
SOURCE
Applied Physics Letters;1/26/2004, Vol. 84 Issue 4, p625
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
We demonstrate a thin-film, solid-state refrigerator based on the removal of hot electrons from a metal by quantum-mechanical tunneling. We have reduced the electronic temperature in a metal film from 260 to ∼130 mK. The base temperature of the device is predicted to increase to near 140 mK under a power load of 10 pW. Both the cooling power and temperature reduction of the refrigerator are well matched to practical applications. This refrigerator will make high-performance cryogenic photon sensors more accessible to the astronomical and analytical communities.
ACCESSION #
12020863

 

Related Articles

  • Magnetic regenerator material economizing method for 4K Gifford-McMahon cryocoolers using bakelite rod. Masuyama, S.; Nagao, T.; Numazawa, T. // AIP Conference Proceedings;Jan2014, Vol. 1573, p1162 

    Magnetic regenerator materials, such as HoCu2, Er3Ni, Gd2O2S, and so on, are always needed to produce the cooling power at the temperature of 4.2 K using regenerative cryocoolers. The use of a large quantity of magnetic regenerator materials affects directly the fabrication cost of 4K...

  • Development and experimental results on a 15 K high frequency pulse tube cold finger. Duval, Jean-Marc; Charles, Ivan // AIP Conference Proceedings;6/8/2012, Vol. 1434 Issue 1, p1040 

    Future space missions such as IXO would benefit from a pulse tube cooler providing several hundreds milliwatts of cooling power at 15 K for the pre cooling of a Joule Thomson loop. Our team, in partnership with Air Liquide and Thales Cryogenics BV, is involved in the development of such a...

  • Preliminary results of a single stage stirling-type pulse tube cooler for multi-hundred watt cooling power at 80 K. Yu, Lihong; Dai, Wei; Wang, Xiaotao; Hu, Jianying; Luo, Ercang // AIP Conference Proceedings;6/8/2012, Vol. 1434 Issue 1, p206 

    No abstract available.

  • Idealized Closed Form Performance Modeling of a Closed Cycle Joule-Thomson Cryocooler. Maytal, B-Z. // AIP Conference Proceedings;2004, Vol. 710 Issue 1, p1669 

    The characteristic parameters of a closed cycle Joule-Thomson cryocooler would be: the charging pressure, discharge and suction volumes of the loop, volumetric displacement of the compressor and the extent of throttling restriction. A series of idealizing assumption are applied. The volumetric...

  • Anomalous Temperature and Amplitude-Dependent Performance Characteristic of a 1000W/80K Coldfinger. Spoor, P. S. // AIP Conference Proceedings;Jan2014, Vol. 1573, p1405 

    A large acoustic-Stirling ('pulse tube') coldfinger designed for approximately 1000 W cooling power at 80 K has shown a distinct decline in efficiency as input power is increased, especially at lower temperatures. Anomalies in the temperature profile around the regenerator circumference are...

  • Low-temperature formation of YBa[sub 2]Cu[sub 3]O[sub 7-x] superconducting films from molecular.... Rupich, M.W.; Liu, Y.P. // Applied Physics Letters;3/16/1992, Vol. 60 Issue 11, p1384 

    Investigates the low temperature formation of YBa[sub 2]Cu[sub 3]O[sub 7-x] superconducting thin films. Precursors of the developed films; Use of standard spin-coating techniques in the deposition process; Determination of the electrical properties and surface morphology of the films.

  • Options and outlook for chiller refrigerants. Calm, James M. // Engineered Systems;May2001, Vol. 18 Issue 5, p88 

    Focuses on the challenges associated in the selection of refrigerants. Relevance of considering the service warranty of refrigerants; Functionality of refrigerants in refrigeration systems; Environmental impact of the use of refrigerants; Factors to consider in the selection of refrigerants.

  • Dark matter search in the EDELWEISS experiment using a 320 g ionization-heat Ge-detector. Navick, X.-F.; Benoit, A.; Berge´, L.; Broniatowski, A.; Chambon, B.; Chapellier, M.; Chardin, G.; Charvin, P.; De Je´sus, M.; Drain, D.; Dumoulin, L.; Gascon, J.; Gerbier, G.; Goldbach, C.; Goyot, M.; Gros, M.; Hadjout, J-P.; Herve´, S.; Juillard, A.; de Lesquen, A. // AIP Conference Proceedings;2002, Vol. 605 Issue 1, p489 

    The EDELWEISS collaboration has performed a direct search for WIMPs using a 320g ionization-heat Ge-cryogenic detector operated in a low-background environment in the Laboratoire Souterrain de Modane. No nuclear recoils events are observed in the fiducial volume in the 30-200 keV energy range...

  • Development of cryogenic detectors for GNO. Lachenmaier, T.; Feilitzsch, F. v.; Jagemann, T.; Jochum, J.; Lanfranchi, J.-C.; Potzel, W.; Ru¨dig, A.; Schnagl, J.; Stark, M.; Wulandari, H. // AIP Conference Proceedings;2002, Vol. 605 Issue 1, p465 

    The neutrino capture reaction [sup 71]Ga(v[sub e],e[sup -])[sup 71] Ge and the reverse EC-decay is used by GNO to monitor the flux of solar neutrinos in a routinely operating neutrino observatory. Low temperature detectors (LTDs) offer a better performance concerning efficiency, energy...