TITLE

The electrothermal heating tube membrane resistance test method research

AUTHOR(S)
XiLin Zhu; Gang Li
PUB. DATE
January 2016
SOURCE
Key Engineering Materials;2016, Vol. 667, p413
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
This thesis uses a kind of detection method: The two ends of the measurement period from two electrodes, and the probe spacing can be adjusted. Two measuring end head into the interior with electric heat pipe membrane contact, used the voltage dividing circuit-relations indirect detection of electric resistance film ends with the two measuring pitch. Then the measured data analysis, obtains the relationship between the two electrode spacing and the electrothermal membrane resistance. Make this thought method may not be used to measure the electric heating film resistance, become a simple and practical method for measuring the electric heating film resistance. Using this method, the measured data can be analyzed, indirectly electrothermal film heating pipe internal resistance value and the two measurement of the end head distance is linear change. The linear relationship between the use of electrothermal film heating tube internal electric heating film resistance, the resistance can be estimated from the distance between the two electrodes, get the change range of heating tube power.
ACCESSION #
110337531

 

Related Articles

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics