TITLE

Accurate three-dimensional shape and deformation measurement at microscale using digital image correlation

AUTHOR(S)
Maodong Ren; Jin Liang; Leigang Li; Bin Wei; Lizhong Wang; Zhengzong Tang
PUB. DATE
July 2015
SOURCE
Review of Scientific Instruments;Jul2015, Vol. 86 Issue 7, p1
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Based on stereomicroscope and three-dimensional (3D) digital image correlation (DIC) method, a non-contact measurement technique is presented to measure the 3D shape and deformation data on miniature specimens and the corresponding microscopic measurement system is developed. A pair of cameras is mounted on a binocular stereo light microscope to acquire pairing micrographs from two different optical paths of a specimen surface spraying with speckle pattern. Considering complex optical paths and high magnification, an accurate equivalent relative calibration method, combining a priori warping functions, is proposed to correct image distortions and optimize the intrinsic and extrinsic parameters of stereomicroscope. Then, a fast one-dimensional synchronous stereo matching method, based on the DIC method and image rectification technique, is proposed to search for discontinuous corresponding points in the pairing micrographs. Finally, the 3D shape is reconstructed from the corresponding points, while the temporal micrographs acquired before and after deformation are employed to determine the full-field deformation. The effectiveness and accuracy of the presented microscale measurement technique are verified by a series of experiments.
ACCESSION #
108464224

 

Related Articles

  • Determination of correct reference fluorescence lifetimes by self-consistent internal calibration. Castelli, Francesco // Review of Scientific Instruments;Apr1985, Vol. 56 Issue 4, p538 

    A method of internal calibration is developed that allows one to ascertain the monexponentiality of a reference compound fluorescence decay and to determine its lifetime with high accuracy. It is shown that when the fluorescence decays of several samples are analyzed as a function of the...

  • Development of standard operating procedures for differential scanning calorimeters. Callanan, Jane E.; Sullivan, Sandra A. // Review of Scientific Instruments;Oct86, Vol. 57 Issue 10, p2584 

    This paper describes an assessment of the behavior of a differential scanning calorimeter and the development of satisfactory calibration, operation, and data reduction procedures, which depend on performance characteristics of the individual instrument. Factors that contribute to thermal lag...

  • Neutron calibration techniques for comparison of tokamak results. Strachan, J. D.; Adams, J. M.; Barnes, Cris W.; Batistoni, P.; Bosch, H.-S.; Brzosko, J. S.; England, A. C.; Fiore, C. L.; Granetz, R. S.; Hendel, H. W.; Hoenen, F.; Jarvis, O. N.; Jassby, D. L.; Ku, L. P.; Liu, P.; Martin, G.; McCauley, S.; Motley, R. W.; Nishitani, T. // Review of Scientific Instruments;Nov90, Vol. 61 Issue 11, p3501 

    A workshop on 1–3 August 1989 reviewed the techniques, uncertainties, and experiences of neutron calibration on PLT, TFTR, JET, Tore Supra, JT-60, JIPPT-IIU, Alcator C-Mod, ATF, FT, ASDEX, Textor, and DIII-D. In the summary session, the workshop participants discussed possible consensus...

  • Calibration of a Mott electron polarimeter: Comparison of different methods. Mayer, S.; Fischer, T.; Blaschke, W.; Kessler, J. // Review of Scientific Instruments;Apr93, Vol. 64 Issue 4, p952 

    The accuracy of the calibration of a Mott polarimeter with a recently suggested method that uses an auxiliary target is compared with the accuracy obtained with the classical double-scattering experiment in its improved form. It turns out that the former method is affected by depolarization of...

  • Erratum: "Power spectrum and Allan variance methods for calibrating single-molecule video-tracking instruments" [Rev. Sci. Instrum. 83, 025115 (2012)].  // Review of Scientific Instruments;2014, Vol. 85 Issue 1, p1 

    A correction to the article "Power Spectrum and Allan Variance Methods for Calibrating Single-Molecule Video-Tracking Instruments" published in a previous issue of "Review of Scientific Instruments" is presented.

  • Combining ferromagnetic resonator and digital image correlation to study the strain induced resonance tunability in magnetoelectric heterostructures. Zighem, Fatih; Belmeguenai, Mohamed; Faurie, Damien; Haddadi, Halim; Moulin, Johan // Review of Scientific Instruments;2014, Vol. 85 Issue 10, p1 

    This paper reports the development of a methodology combining microstrip ferromagnetic resonance and digital image correlation in order to simultaneously measure the voltage-induced strains and the magnetic resonance in artificial magnetoelectric heterostructures ("magnetic films/piezoelectric...

  • Novel scanning electron microscope bulge test technique integrated with loading function. Chuanwei Li; Zhanwei Liu; Huimin Xie // Review of Scientific Instruments;2014, Vol. 85 Issue 10, p1 

    Membranes and film-on-substrate structures are critical elements for some devices in electronics industry and for Micro Electro Mechanical Systems devices. These structures are normally at the scale of micrometer or even nanometer. Thus, the measurement for the mechanical property of these...

  • Fluorescent reference standard.  // Laboratory Equipment;Dec99, Vol. 36 Issue 8, p1 

    Features Precision Dynamics Corp.'s Fluorescent Reference Standards for the calibration of assay instrumentation. Use in measurement and testing procedures in forensic, biotechnology and biological research laboratories; Microtiter plate format; Reference plates offered.

  • Calibration of the torsional spring constant and the lateral photodiode response of frictional force microscopes. Feiler, Adam; Attard, Phil; Larson, Ian // Review of Scientific Instruments;Jul2000, Vol. 71 Issue 7 

    We present a direct one-step technique to measure the torsional spring constant of cantilevers used for lateral or friction measurements with the atomic force microscope. The method simultaneously calibrates the photodiode response to the angular deflection of the cantilever. It does not rely...