ABSTRACT
Objectives. The American–European consensus conference (AECC) definition for acute respiratory distress syndrome (ARDS) requires a PaO2/FIO2≤200 mmHg, regardless of ventilator settings. We report the results of using standardized ventilator settings to screen and enroll ARDS patients in a clinical trial of high-frequency oscillatory ventilation (HFOV), including the impact on study enrollment, and potential effects on study outcome. Design. Prospective cohort study. Setting. Intensive care units in two teaching hospitals. Participants. A consecutive sample of 41 patients with early ARDS by AECC criteria (baseline PaO2/FIO2≤200) who met all other inclusion/exclusion criteria for the HFOV trial. Interventions. Patients were placed on standardized ventilator settings (tidal volume 7–8 ml/kg, PEEP 10 cmH2O, FIO2 1.0), and the PaO2/FIO2 was reassessed after 30 min. Results. Seventeen patients (41.5%) had PaO2/FIO2 ratios that remained ≤200 mmHg [Persistent ARDS; PaO2/FIO2=94±36 (mean±SD)] and went on to inclusion in the HFOV study; however, in 24 patients (58.5%) the PaO2/FIO2 was >200 mmHg [Transient ARDS; PaO2/FIO2=310±74] and these patients were ineligible for the HFOV study. The ICU mortality was significantly greater (52.9 vs 12.5%; p=0.01) in the Persistent ARDS patients. Conclusions. The use of these standardized ventilatory significantly impacted the PaO2/FIO2 ratio and therefore the ARDS prevalence and trial enrollment. These results have effects on the evaluation of the current ARDS literature and conduct of clinical trials in ARDS and hence consideration should be given to the use of standardized ventilatory settings in future ARDS trials.
ACCESSION #
10501275

 

Related Articles

  • Screening of ARDS patients using standardized ventilator settings: influence on enrollment in a clinical trial. Ferguson, Niall D.; Kacmarek, Robert M.; Chiche, Jean-Daniel; Singh, Jeffrey M.; Hallett, David C.; Mehta, Sangeeta; Stewart, Thomas E. // Intensive Care Medicine;Jun2004, Vol. 30 Issue 6, p1111 

    Objectives. The American–European consensus conference (AECC) definition for acute respiratory distress syndrome (ARDS) requires a PaO2/FIO2≤200 mmHg, regardless of ventilator settings. We report the results of using standardized ventilator settings to screen and enroll ARDS...

  • Critical Care Medicine.  // Clinical & Investigative Medicine;Dec98 Supplement, Vol. 21, pS24 

    The article presents various studies related to critical care medicine. These studies include the efficacy of the drug fenoldopam, the utility of echocardiography in intensive care, infection control in intensive care units and agreement among accepted research criteria for the diagnosis of...

  • Model-based optimal PEEP in mechanically ventilated ARDS patients in the Intensive Care Unit.  // BioMedical Engineering OnLine;2011, Vol. 10 Issue 1, p64 

    The article presents a research paper which analyzes the feasibility of models that consider optimal level of positive end-expiratory pressure (PEEP) for the treatment of acute respiratory distress syndrome (ARDS) patients in the Intensive Care Unit. These methods of selecting PEEP offers a...

  • Potentially harmful effects of inspiratory synchronization during pressure preset ventilation. Richard, J.; Lyazidi, A.; Akoumianaki, E.; Mortaza, S.; Cordioli, R.; Lefebvre, J.; Rey, N.; Piquilloud, L.; Sferrazza-Papa, G.; Mercat, A.; Brochard, L. // Intensive Care Medicine;Nov2013, Vol. 39 Issue 11, p2003 

    Purpose: Pressure preset ventilation (PPV) modes with set inspiratory time can be classified according to their ability to synchronize pressure delivery with patient's inspiratory efforts (i-synchronization). Non-i-synchronized (like airway pressure release ventilation, APRV), partially...

  • Influence of selenium supplements on the post-traumatic alterations of the thyroid axis: a placebo-controlled trial. Berger, M. M.; Reymond, M. J.; Shenkin, A.; Rey, F.; Wardle, C.; Cayeux, C.; Schindler, C.; Chioléro, R. L. // Intensive Care Medicine;Jan2001, Vol. 27 Issue 1, p91 

    Objective: To investigate whether early selenium (Se) supplementation can modify the post-traumatic alterations of thyroid hormone metabolism, since the first week after trauma is characterised by low plasma Se and negative Se balances. Design: Prospective, placebo-controlled randomised...

  • Lung-protective mechanical ventilation strategies in ARDS. Lee, W. L.; Detsky, A. S.; Stewart, T. E. // Intensive Care Medicine;Aug2000, Vol. 26 Issue 8, p1151 

    The article discusses the characteristics of acute respiratory distress syndrome (ARDS). Effect of mechanical ventilation on the degree of lung injury; Measurement process in determining the ideal tidal volume and the level of positive end-expiratory pressure (PEEP); Examination on the effect of...

  • Analysis of Variance (ANOVA) Models in Emergency Medicine. Reed III, James F. // Internet Journal of Emergency & Intensive Care Medicine;2004, Vol. 7 Issue 2, p11 

    Four basic analysis of variance (ANOVA) designs are reviewed in this paper. Hypothetical examples drawn from the literature to illustrate a single factor ANOVA design, two a repeated measures ANOVA designs, and a randomized block ANOVA design. ANOVA designs provide "life beyond t-tests". These...

  • Getz Gives "Gift of Participation". Etkin, Samantha // Applied Clinical Trials;Feb2008, Vol. 17 Issue 2, p18 

    The article reports on the issue concerning involvement of people in the U.S. on clinical studies. It reports the fact that majority of people in the country are unaware of the importance of clinical trials in the development of new, life-saving medications and devices. It adds that most people...

  • Advancing Patient Safety Through Human Factors Engineering. Gieras, Izabella; Ebben, Steve // Medical Design Technology;Feb2007, Vol. 11 Issue 2, p30 

    The article discusses the advancement of patient safety through human factors engineering. According to the author, it is in the best interest of healthcare providers to receive technology that has been thoroughly tested to ensure successful implementation into an existing environment. Hospitals...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics