TITLE

Holographic optical coherence imaging of tumor spheroids

AUTHOR(S)
Yu, P.; Mustata, M.; Turek, J. J.; French, P. M. W.; Melloch, M. R.; Nolte, D. D.
PUB. DATE
July 2003
SOURCE
Applied Physics Letters;7/21/2003, Vol. 83 Issue 3, p575
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
We present depth-resolved coherence-domain images of living tissue using a dynamic holographic semiconductor film. An AlGaAs photorefractive quantum-well device is used in an adaptive interferometer that records coherent backscattered (image-bearing) light from inside rat osteogenic sarcoma tumor spheroids up to 1 mm in diameter in vitro. The data consist of sequential holographic image frames at successive depths through the tumor represented as a visual video "fly-through." The images from the tumor spheroids reveal heterogeneous structures presumably caused by necrosis and microcalcifications characteristic of human tumors in their early avascular growth.
ACCESSION #
10281573

 

Related Articles

  • Crosstalk caused by incoherence of the readout light in wavelength-division multiplexing of reflection holograms. Chamrai, A. V.; Petrov, V. M.; Petrov, M. P. // Technical Physics;Sep99, Vol. 44 Issue 9, p1098 

    The effect of incoherence of the readout light on the level of crosstalk in wavelength-division multiplexing of reflection holograms is studied. The level of crosstalk is determined theoretically as a function of the spectral width of the readout light, the total number of multiplexed holograms,...

  • The Göttingen Holography Endstation of Beamline P10 at PETRA III/DESY. Kalbfleisch, S.; Neubauer, H.; Krüger, S. P.; Bartels, M.; Osterhoff, M.; Mai, D. D.; Giewekemeyer, K.; Hartmann, B.; Sprung, M.; Salditt, T. // AIP Conference Proceedings;9/9/2011, Vol. 1365 Issue 1, p96 

    We report the commissioning of the novel holography endstation for the P10 coherence beamline at PETRA III at DESY. The experimental imaging scheme is based on a highly coherent and divergent (cone) beam illumination, achieved by fixed-curvature focusing mirrors with additional spatial and...

  • Laser-Powered Video.  // Technotrends Newsletter;Jun2012, Vol. 28 Issue 6, p1 

    The article provides information on the low-coherence laser in which the light waves are reflected off of random particles suspended in a fluid and can be used in medical imaging and video projection.

  • Retinal imaging advancements will guide future treatments. Charters, Lynda // Ophthalmology Times;6/1/2002, Vol. 27 Issue 11, p13 

    Describes present and future imaging technologies as of June 2002. Importance of high-resolution structural imaging; Advantage of optical coherence tomography; Function of the retinal thickness analyzer.

  • Superimposed volume holograms for measuring the phase and degree of mutual coherence of a light wave. Orlov, V. V. // Optics & Spectroscopy;Jan2010, Vol. 108 Issue 1, p133 

    Superimposed volume holograms, which make it possible to determine the phase and degree of mutual coherence of a stationary light wave consisting of partially coherent plane components incident on the holograms at different angles are proposed. To find these parameters of the light wave, the...

  • Secondary retinal changes associated with choroidal naevi and melanomas documented by optical coherence tomography. Muscat S; Parks S; Kemp E; Keating D // British Journal of Ophthalmology;Jan2004, Vol. 88 Issue 1, p120 

    AIMS: To establish the characteristics of secondary retinal changes associated with the presence of choroidal melanomas and choroidal naevi as documented by optical coherence tomography (OCT). METHODS: Twenty patients with untreated choroidal melanoma and 40 patients with presumed choroidal...

  • Holography and Coherent Optics (Book). Stark, Henry // American Scientist;May/Jun82, Vol. 70 Issue 3, p330 

    Reviews the non-fiction book 'Holography and Coherent Optics,' by L.M. Soroko and translated by Albin Tybulewicz.

  • Excess coherence. Levenson, M. David // Microlithography World;Feb2007, Vol. 16 Issue 1, p20 

    The author reflects on excessive coherence in lithography. Coherence can be defined as the extent to which the exposure dose due to two features is greater or less than those that are attributable to each feature exposed separately. The two kinds of partial coherence common in lithography are...

  • Resolution and Field of View Improvement Using Information Coding. García, Javier; Mico, Vicente; Zalevsky, Zeev; García-Martínez, Pascuala; Ferreira, Carlos // AIP Conference Proceedings;10/24/2007, Vol. 949 Issue 1, p177 

    In this paper we propose and discuss new approaches to improve resolution and field of view of an aperture limited imaging system. The key idea is to perform object information coding previously the imaging system. By properly definition of such coding stage, it is possible to transmit...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics