TITLE

Comparison of Emissive and Plugged Probes DC Plasma Potential Measurements in a Magnetised Plasma

AUTHOR(S)
Greiner, F.; Block, D.; Piel, A.; Ratynskaja, S.; Helblom, G.; Rypdal, K.
PUB. DATE
June 2003
SOURCE
AIP Conference Proceedings;2003, Vol. 669 Issue 1, p64
SOURCE TYPE
Conference Proceeding
DOC. TYPE
Article
ABSTRACT
Measurements of DC plasma potential profile with emissive and plugged probe were carried out for different experimental conditions in the Simple Magnetised Torus Devices BLAAMANN and TEDDI. The comparison of the data shows, that after a proper check of the probe alignment, the plugged probe can be an durable and easy to use alternative.
ACCESSION #
10220657

 

Related Articles

  • Dust grains as a Diagnostic Tool for RF-Discharge Plasma. James, B. W.; Samarian, A. A.; Tsang, W. // AIP Conference Proceedings;2003, Vol. 669 Issue 1, p90 

    Dust particles can be a useful plasma diagnostic tool. Sufficiently dust particles can be used as test grains for the visualization of the plasma potential distribution; larger dust particles can be used as specific probes to determine electron temperature. Here we report on diagnostic...

  • Three-dimensional modeling and inversion of x-ray pinhole detector arrays. Tritz, K.; Stutman, D.; Delgado-Aparicio, L.; Finkenthal, M. // Review of Scientific Instruments;Oct2006, Vol. 77 Issue 10, p10F510 

    X-ray pinhole detectors are a common and useful diagnostic for high temperature and fusion-grade plasmas. While the measurements from such diagnostics are line integrated, local emission can be recovered by inverting or modeling the data using varying assumptions including toroidal symmetry,...

  • Plasma Diagnostics at the Angara-5-1 Facility. Volkov, G. S.; Grabovskii, E. V.; Zaitsev, V. I.; Zukakishvili, G. G.; Zurin, M. V.; Mitrofanov, K. N.; Nedoseev, S. L.; Oleinik, G. M.; Porofeev, I. Yu.; Smirnov, V. P.; Frolov, I. N. // Instruments & Experimental Techniques;Mar/Apr2004, Vol. 47 Issue 2, p201 

    The set of diagnostic techniques used at the Angara-5-1 facility that make it possible to study the processes which accompany the ultrafast current-driven implosion of liners is described. This set includes electric methods and methods for the detection of various radiations. The liner-plasma...

  • Contact Diagnostics of High-Velocity Flows of Rarefied Plasma. Shuvalov, V.; Kochubei, G.; Priimak, A.; Reznichenko, N.; Tokmak, N.; Lazuchenkov, D. // High Temperature;May2005, Vol. 43 Issue 3, p335 

    A procedure is developed of the diagnostics of supersonic flows of nonequilibrium rarefied plasma. It is experimentally confirmed that the application of pressure probes and Langmuir probes makes it possible to determine almost the entire complex of basic kinetic parameters of nonequilibrium...

  • Edge plasma measurements near the minimum-B anchor cell of GAMMA10 using Langmuir probe and calorimeter arrays. Nakashima, Y.; Islam, M. K.; Natori, T.; Katanuma, I.; Ohki, T.; Watanabe, K.; Higashizono, Y.; Cho, T.; Ishimoto, Y. // Review of Scientific Instruments;Oct2004 Part I & II, Vol. 75 Issue 10, p4308 

    Edge plasma diagnostic system equipped in minimum-B anchor cell of the GAMMA10 tandem mirror is described together with the measured results. Several sets of the diagnostic element consisting of a Langmuir probe and a calorimeter are placed in array on the conducting plates installed in the east...

  • Scanning internal probe for plasma particle, fluctuation, and LIF tomographic measurements. Biloiu, Costel; Scime, Earl; Xuan Sun; McGeehan, Brendan // Review of Scientific Instruments;Oct2004 Part I & II, Vol. 75 Issue 10, p4296 

    An internal scanning probe capable of spatially resolved measurements throughout a horizontal (r,z) cross section of the expansion region between a helicon plasma source and an expansion chamber is described. For complete diagnosis of the expanding magnetoplasma, the probe is designed to...

  • On the interpretation of fluctuation and E×B turbulent transport measured by Langmuir probes in fusion plasmas. Calderón, E.; Hidalgo, C.; Pedrosa, M. A.; Silva, C. // Review of Scientific Instruments;Oct2004 Part I & II, Vol. 75 Issue 10, p4293 

    Plasma fluctuations and fluctuation-induced particle fluxes have been investigated in the plasma edge of the TJ-II stellarator using Langmuir probes. Simultaneous measurements of plasma fluctuations carried out by probes located in and out of the probe body sheath show similar results in the...

  • On the use of MHD mode analysis as a technique for determination of q-profiles in JET plasmas. Nave, M. F. F.; Borba, D.; Galvão, R.; Hacquin, S.; Alper, B.; Challis, C.; Gerasimov, S.; Hawkes, N.; Mailloux, J.; Sharapov, S.; Boswell, C.; Brix, M.; Joffrin, E.; de la Luna, E.; Smeulders, P. // Review of Scientific Instruments;Oct2004 Part I & II, Vol. 75 Issue 10, p4274 

    JET plasmas show fluctuations from a large variety of MHD instabilities. A combination of spectral analysis, mode number analysis, and determination of mode radial position has the potential as a diagnostic for the plasma q profile. Mode frequencies and mode numbers are obtained from spectral...

  • Point-to-point analysis of MSE data for plasma diagnostics and control. Giannella, R.; Hawkes, N. C.; Jayakumar, R.; Makowski, M.; Zabeo, L. // Review of Scientific Instruments;Oct2004 Part I & II, Vol. 75 Issue 10, p4247 