TITLE

Neurological and neuropsychological examination and outcome after use of an intra-aortic filter device during cardiac surgery

AUTHOR(S)
Eifert, S; Reichenspurner, H; Pfefferkorn, T; Baur, B; von Schlippenbach, C; Mayer, TE; Hamann, G; Reichart, B
PUB. DATE
March 2003
SOURCE
Perfusion;Mar2003 Supplement, Vol. 18, p55
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Cerebral embolization of particles after cardiac surgery is frequently associated with neurological deficits. Aortic crossclamp manipulation seems to be the most significant cause of emboli release during cardiac surgery. The goal of this study was to demonstrate whether the use of an intra-aortic filter device has an effect on the magnet resonance imaging (MRI) and functional neurological outcome. Twenty-four patients undergoing cardiosurgical procedures using cardiopulmonary bypass (CPB) were selected: coronary artery bypass graft (CABG) surgery (n = 17), aortic valve replacement (AVR) surgery (n = 4) or combined procedures (n = 3). Patients were evaluated by diffusion weighted MRI of the brain, neurological examination and neuropsychological assessment regarding alertness as well as divided and selective attention before and five to seven days after surgery. The patients were divided into two groups. In group I, 12 patients received a filter through a modified 24 F arterial cannula immediately before the aortic crossclamp was released. Filters remained in the aorta until CPB was discontinued. Intraoperatively, bilateral middle cerebral artery transcranial Doppler (TCD) was monitored at baseline, at the beginning of CPB, at a timepoint when the aorta was crossclamped, when the filter was inserted and while the crossclamp was switched to partial clamping until the CPB was discontinued. TCD was used for detection of microembolic signals (MES). The captured material in the filter was examined histologically. Twelve patients served as controls without aortic filtration (group II). The MRI of the brain did not show any diffusion alterations in either group before or after surgery. No patient developed a focal neurological deficit or stroke. Intraoperative quantitative MES detection revealed a four to tenfold increase in patients of group I compared with group II (5-6 versus 0.5-1 MES/min) during the filter dwell time. There was no consistent pattern regarding the...
ACCESSION #
10051393

 

Related Articles

  • INTRACORONARY ULTRASOUND IN THE EVALUATION OF LEFT MAIN CORONARY ARTERY STENOSIS.  // Heart;May2001 Supplement 1, Vol. 85, pP52 

    This article focuses on a study related to the intracoronary ultrasound in the evaluation of left main coronary artery stenosis. Observation of intermediate or indeterminate severity left main coronary artery (LMCA) stenosis in patients undergoing coronary angiography is a common clinical...

  • Initial Experience with Beating Heart Surgery: Comparison with Fast-Track Methods. Ott, Richard A.; Gutfinger, Dan E. // American Surgeon;Nov1999, Vol. 65 Issue 11, p1018 

    Cardiopulmonary bypass (CPB) in coronary artery bypass grafting (CABG) may increase postoperative complications in high-risk patients. The goal of this study is to retrospectively review a series of consecutive patients undergoing conventional CABG using a fast-track recovery method and to...

  • New Coronary Artery Bypass Options.  // USA Today Magazine;Oct2001, Vol. 130 Issue 2677, p4 

    Focuses on the popularity of the use of off-pump heart surgery in coronary artery bypass operations. Advantages of the technique.

  • Coronary artery bypass graft with biventricular microaxial pumps. Meyns, B.; Sergeant, P. // Perfusion;1999, Vol. 14 Issue 4, p288 

    Investigates the use of biventricular microaxial pumps for coronary artery bypass graft procedure. Information on the mechanical support system; Intended clinical use of the device.

  • Editorial To risk or not to risk. Punjabi, Prakash P. // Perfusion;Sep2008, Vol. 23 Issue 5, p253 

    The article discusses various reports published within the issue including one on the use of decision analysis and meta analysis in predicting outcomes in coronary artery bypass grafting surgery, and another one about ECHO parameters of diastolic dysfunction and the effect of clenbuterol...

  • Angioplasty safe without cardiac surgery backup.  // OR Manager;Jan2012, Vol. 28 Issue 1, p23 

    The article reports that percutaneous coronary interventions (PCIs) performed at hospital without surgical backup, do not increase the in-hospital mortality or the requirement of the emergency coronary bypass surgery in the U.S.

  • CARDIAC BYPASS without the pump. Munro, Nancy // RN;Oct2003, Vol. 66 Issue 10, p28 

    Focuses on off-pump coronary artery bypass. Surgery for coronary artery disease patients; Risk and advantages of the machine; Inflammatory response; Assessment for postop complications; Other organs affected. INSET: Systemic inflammatory response syndrome..

  • Heart of the matter. Milton, Philip // Money Marketing;1/21/2010, p40 

    In this article the author reflects on his triple heart bypass surgery relative to those people who decided to sell their businesses and give up their jobs.

  • Is coronary bypass surgery really safe? CHUA, PHILIP S. // Filipino Reporter;6/6/2014, Vol. 42 Issue 27, p35 

    The article presents questions and answers related to coronary bypass surgery including whether heart bypass is an open heart surgery or not, whether the heart has to be stopped during surgery or not, and the concept of Robotic heart surgery.

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics