TITLE

Latent Heating Contribution from Precipitation Systems with Different Sizes, Depths, and Intensities in the Tropics

AUTHOR(S)
Liu, Chuntao; Shige, Shoichi; Takayabu, Yukari N.; Zipser, Edward
PUB. DATE
January 2015
SOURCE
Journal of Climate;Jan2015, Vol. 28 Issue 1, p186
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Latent heating (LH) from precipitation systems with different sizes, depths, and convective intensities is quantified with 15 years of LH retrievals from version 7 Precipitation Radar (PR) products of the Tropical Rainfall Measuring Mission (TRMM). Organized precipitation systems, such as mesoscale convective systems (MCSs; precipitation area > 2000 km2), contribute to 88% of the LH above 7 km over tropical land and 95% over tropical oceans. LH over tropical land is mainly from convective precipitation, and has one vertical mode with a peak from 4 to 7 km. There are two vertical modes of LH over tropical oceans. The shallow mode from about 1 to 4 km results from small, shallow, and weak precipitation systems, and partially from congestus clouds with radar echo top between 5 and 8 km. The deep mode from 5 to 9 km is mainly from stratiform precipitation in MCSs. MCSs of different regions and seasons have different LH vertical structure mainly due to the different proportion of stratiform precipitation. MCSs over ocean have a larger fraction of stratiform precipitation and a top-heavy LH structure. MCSs over land have a higher percentage of convective versus stratiform precipitation, which results in a relatively lower-level peak in LH compared to MCSs over the ocean. MCSs during monsoons have properties of LH in between those typical land and oceanic MCSs. Consistent with the diurnal variation of precipitation, tropical land has a stronger LH diurnal variation than tropical oceans with peak LH in the late afternoon. Over tropical oceans in the early morning, the shallow mode of LH peaks slightly earlier than the deep mode. There are almost no diurnal changes of MCSs LH over oceans. However, the small convective systems over land contribute a significant amount of LH at all vertical levels in the afternoon, when the contribution of MCSs is small.
ACCESSION #
100208416

 

Related Articles

  • Passive Solar Heating: its Role in Architectural Shaping. Murgul, Vera; Komatina, Dragan; Nikolić, Vojislav; Vatin, Nikolay // Applied Mechanics & Materials;2014, Vol. 740, p1552 

    A notion 'passive solar building design' has been arisen so far. In fact, it means heat flows management using architectural shaping. Architectural shaping is based on logic of heat flows generation and movement. Nowadays, an architectural form has no direct relation to a structure as close as...

  • The Influence of Thermal Bridges on the Energy Need for Heating after Renewal: A Case Study. Menďan, Rastislav; Pavčeková, Monika // Applied Mechanics & Materials;2016, Vol. 824, p307 

    The contribution deals with the influence of additional heat loss caused by thermal bridges of a building on the energy need for heating. Calculations and comparisons were carried out for a simple characteristic family house built in the sixties in the last century. The family house was...

  • Run-Around Heat Recovery System Using Cross-Flow Flat-Plate Heat Exchangers with Aqueous Ethylene Glycol as the Coupling Fluid. Haisheng Fan; Besant, Robert W.; Simonson, Carey J.; Wei Shang // ASHRAE Transactions;2005, Vol. 111 Issue 1, p901 

    A two-dimensional steady-state mathematical model is developed from physical principles to study heat transport of a run-around heat recovery system for air-to-air heat recovery in HVAC applications. A finite difference method is employed to solve the governing equations of the cross-flow...

  • Determination of the Critical Duration of the First Heating of Heavy Concrete by the Criterion of the Maximum Strength Reduction. Korsun, Volodymyr; Korsun, Artem; Mashtaler, Sergey // Applied Mechanics & Materials;2014, Vol. 740, p566 

    The article introduces the results of the experimental research of the duration of the first heating of concrete at temperatures of +90° and +150°C causing the maximum reduction of its strength during the subsequent axial compression.

  • APPLICATION WITH SIMULTANEOUS ELECTROCONTACT HEATING STRETCHING TO REDUCE RESIDUAL STRESSES IN THE HEAT EXCHANGE TUBE. SHIMOV, Georgy; SEREBRYAKOV, Andrey; SEREBRYAKOV, Alexander // Advanced Materials Research;2015, Vol. 1127, p121 

    The main reason of appearance and growth of corrosion damages of the nuclear steam generator heat exchanger tubes is the process of stress-corrosion cracking of metal under the influence of residual tensile stress. The article contain the suggestion of the method that combines the operation of...

  • Cost-Effective Design of Dual Heat and Energy Recovery Exchangers for 100% Ventilation Air in HVAC Cabinet Units. Asiedu, Yaw; Besant, Robert W.; Simonson, Carey J. // ASHRAE Transactions;2005, Vol. 111 Issue 1, p857 

    This paper shows how a combined air-to-air heat and energy recovery system design problem can be formulated for HVAC cabinet units and solved for the least life-cycle cost system while still retaining a small time period payback. Mathematical expressions are presented to address the complicating...

  • Electron heating mode transition induced by mixing radio frequency and ultrahigh frequency dual frequency powers in capacitive discharges. Sahu, B. B.; Han, Jeon G. // Physics of Plasmas;2016, Vol. 23 Issue 5, p053514-1 

    Electron heating mode transitions induced by mixing the low- and high-frequency power in dualfrequency nitrogen discharges at 400 mTorr pressure are presented. As the low-frequency (13.56 MHz) power decreases and high-frequency (320 MHz) power increases for the fixed power of 200 W, there is a...

  • More important than a tick box exercise. Jackson, Lee // Heating & Ventilating Review;Jun2014, Vol. 53 Issue 8, p24 

    The article focuses on the growing popularity of mechanical ventilation and heat recovery (MVHR) units in Great Britain. Topics include some of the problems for MVHRs like miscommunication between floor joist designers and installers and the ignorance of homeowners about MVHR and how it runs....

  • Mitsi keeps Barrier staff cool -- and dry.  // ACR News: Air Conditioning & Refrigeration News;2007, p4 

    The article reports that staff at the Thames Barrier stayed cool because of the installation of a Mitsubishi City Multi heat recovery air conditioning system by MacWhirter Ltd. as part of a recent refurbishment project. The air conditioning benefits two open plan offices, three conference rooms,...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics