TITLE

Comparison of Unenhanced and Enhanced Imaging Protocols for Angle Measurements With Anterior Segment Optical Coherence Tomography

AUTHOR(S)
Deokule, Sunil; Alencar, Luciana; Vizzeri, Gianmarco; Medeiros, Felipe; Weinreb, Robert N.
PUB. DATE
January 2012
SOURCE
Ophthalmic Surgery, Lasers & Imaging;Jan/Feb2012, Vol. 43 Issue 1, p39
SOURCE TYPE
Academic Journal
DOC. TYPE
Abstract
ABSTRACT
BACKGROUND AND OBJECTIVE: To compare the intraobserver and interobserver agreement of anterior chamber angle measurements using unenhanced and enhanced imaging protocols for anterior segment optical coherence tomography (AS-OCT). PATIENTS AND METHODS: Anterior segments of 30 eyes of 15 healthy subjects (mean age: 33.8 ± 13.0 years, 8 women) were imaged by a single examiner with AS-OCT using unenhanced and enhanced imaging protocol. Two masked observers analyzed each image independently on two separate occasions. The reproducibility of angle parameters was estimated by calculating coefficients of variation separately for each observer. Bland-Altman plots were constructed to assess the intraobserver and interobserver agreement. RESULTS: The intraobserver and interobserver reproducibility was similar between imaging protocols. Intra-observer and interobserver agreements were also similar for all parameters evaluated. The best estimate of scleral spur location was determined in all images by both observers. CONCLUSION: Measurement variability was similar with the unenhanced and enhanced imaging protocol in this series of eyes with open angles.
ACCESSION #
77226923

 

Related Articles

  • OCT-assisted anterior segment surgery safe, accurate.  // Ocular Surgery News;3/25/2010, Vol. 28 Issue 6, p16 

    The article examines how intraoperative online optical coherence tomography imaging with a modified Carl Zeiss Meditec Visante anterior segment optical coherence tomography (OCT) connected to an operating microscope and video recorder can be used to improve the safety and accuracy of a surgery.

  • Taking OCT Technology To the Next Level.  // Review of Ophthalmology;Jun2006, Vol. 13 Issue 6, p30 

    The article focuses on the Optical Coherence Tomography (OCT) as a means to image ocular structures non evasively and identical to ultrasound B-mode. The commercial OCT uses the time domain technology and has been proven to be clinically valuable despite its limitations specially on resolution...

  • Factors affecting imaging of spectral-domain optical coherence tomography in gas-filled eyes after macular-hole surgery. Goto, Katsutoshi; Mizukawa, Kenichi; Kiryu, Junichi // Japanese Journal of Ophthalmology;May2012, Vol. 56 Issue 3, p236 

    Purpose: We investigated factors affecting imaging of spectral-domain optical coherence tomography (SD-OCT) in gas-filled eyes after macular-hole (MH) surgery. Methods: The study comprised 25 eyes in 23 patients, eight men and 15 women, with a mean age of 66.9 (48-77) years, all of whom had...

  • New Tech Adds to, Doesn't Replace Old. Glenn, Christopher // Review of Ophthalmology;Jun2012, Vol. 19 Issue 6, p15 

    The article presents the author's views on new and traditional ocular imaging techniques for diagnosis of glaucomas. He mentions a study from the Michigan-based Kellogg Eye Center which revealed increased use of new techniques as compared to traditional techniques. He mentions several techniques...

  • Spectroscopic OCT by Grating-Based Temporal Correlation Coupled to Optical Spectral Analysis. Froehly, L.; Ouadour, M.; Furfaro, L.; Sandoz, P.; Leproux, P.; Huss, G.; Couderc, V. // International Journal of Biomedical Imaging;2008, p1 

    Spectroscopic optical coherence tomography (spectroscopic OCT) is an echographic-like optical method for biomedical functional imaging. Current spectroscopic optical coherence tomography (OCT) methods rely on a posteriori numerical calculation. We present an alternative for optically accessing...

  • Clinically Isolated Syndromes Suggestive of Multiple Sclerosis: An Optical Coherence Tomography Study. Oreja-Guevara, Celia; Noval, Susana; Alvarez-Linera, Juan; Gabald�n, Laura; Manzano, Beatriz; Chamorro, Beatriz; Diez-Tejedor, Exuperio // PLoS ONE;Mar2012, Vol. 7 Issue 3, p1 

    Background: Optical coherence tomography (OCT) is a simple, high-resolution technique to quantify the thickness of retinal nerve fiber layer (RNFL), which provides an indirect measurement of axonal damage in multiple sclerosis (MS). This study aimed to evaluate RNFL thickness in patients at...

  • Reproducibility of high-resolution optical coherence tomography in multiple sclerosis. Syc, Stephanie B.; Warner, Christina V.; Hiremath, Girish S.; Farrell, Sheena K.; Ratchford, John N.; Conger, Amy; Frohman, Teresa; Cutter, Gary; Balcer, Laura J.; Frohman, Elliot M.; Calabresi, Peter A. // Multiple Sclerosis (13524585);Jul2010, Vol. 16 Issue 7, p829 

    Optical coherence tomography (OCT) is a non-invasive method to quantify neurodegeneration as an outcome in multiple sclerosis clinical trials; however, no data exist on Cirrus spectral domain optical coherence tomography (SD-OCT) reproducibility in patients with multiple sclerosis. The objective...

  • BMLA Woburn 2011.  // Lasers in Medical Science;Nov2011, Vol. 26 Issue 6, p719 

    No abstract available.

  • Fundus autofluorescence and retinal structure as determined by spectral domain optical coherence tomography, and retinal function in retinitis pigmentosa. Iriyama, Aya; Yanagi, Yasuo // Graefe's Archive of Clinical & Experimental Ophthalmology;Mar2012, Vol. 250 Issue 3, p333 

    Background: To investigate the association between fundus autofluorescence (FAF) and retinal structure and function in retinitis pigmentosa (RP). Methods: For image acquisition, HRA2 (Heidelberg Engineering) and 3D-OCT1000 (Topcon Corp.) were used. Based on FAF examination, 88 eyes of 44 RP...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics