TITLE

Initial operation of the divertor Thomson scattering diagnostic on DIII-D (abstract)

AUTHOR(S)
Carlstrom, T. N.; Hsieh, C. L.; Stockdale, R.; Nilson, D. G.; Hill, D. N.
PUB. DATE
January 1997
SOURCE
Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p708
SOURCE TYPE
Academic Journal
DOC. TYPE
Abstract
ABSTRACT
Presents an abstract of a paper reporting on Thomson scattering measurements in the divertor region of a tokamak. Use of the data as input to boundary physics codes such as UEDGE and DEGAS and to benchmark the predictive capabilities of the codes; Characterization of tokamak disruptions; Fiber optics; Silicon avalanche photodiodes.
ACCESSION #
630821

 

Related Articles

  • Initial operation of the divertor Thomson scattering diagnostic on DIII-D. Carlstrom, T.N.; Hsieh, C.L.; Stockdale, R.; Nilson, D.G.; Hill, D.N. // Review of Scientific Instruments;Feb1997, Vol. 68 Issue 2, p1195 

    Details the commissioning of the divertor Thomson scattering (DTS) system for the DIII-D tokamak. Achievement of two-dimensional mapping of the divertor region; Measurement of the scattered and plasma background light; Schematic layout of the DTS diagnostic.

  • Error analysis of Rijnhuizen tokamak project Thomson scattering data. Beurskens, M.N.A.; Barth, C.J.; Chu, C.C.; Lopes Cardozo, N.J. // Review of Scientific Instruments;Apr99, Vol. 70 Issue 4, p1999 

    Focuses on error analysis of Thomson scattering data at the Rijnhuizen tokamak project in the Netherlands. Overview of the Thomson scattering diagnostic; Error determination; Instrument profile; Convolution of the fit function.

  • Thomson scattering diagnostic for the microwave tokamak experiment. Foote, J. H.; Barter, J. D.; Sewall, N. R.; Jolly, J. J.; Schlander, L. F. // Review of Scientific Instruments;Oct90, Vol. 61 Issue 10, p2861 

    The Thomson scattering diagnostic system (TSS) on the microwave tokamak experiment (MTX) at LLNL routinely monitors electron temperature (T[sub e]) and density. Typical measured values at the plasma center under clean conditions are 900 ± 70 eV and 1-2 × 10[sup 14] (± 30%) cm[sup -3]....

  • TFTR edge Thomson scattering system. Johnson, D.; Grek, B.; Dimock, D.; Palladino, R.; Tolnas, E. // Review of Scientific Instruments;Aug1986, Vol. 57 Issue 8, p1810 

    A system is under construction which will make use of the laser and collection optics of an existing multichannel Thomson scattering system on the tokamak fusion test reactor (TFTR). A scanning sampling mechanism wilt divert signal from a 10-cm segment of the radial-beam path to a...

  • Design and operation of a low cost, reliable millimeter-wave interferometer. Porte, L.; Rettig, C.L.; Pebbles, W.A.; Ngyuen, X. // Review of Scientific Instruments;Jan1999, Vol. 70 Issue 1, p1082 

    Presents preliminary data from a reliable millimeter-wave interferometer that has been integrated to operate simultaneously with a collective Thomson scattering system. Frequency chirped source and detector used by the interferometer; Installation of the interferometer on the DIII-D tokamak.

  • Calibration of the Joint European Torus energetic ion and alpha particle collective Thomson... Egedal, Jan; Machuzak, John S.; Fessey, John S.; Bindslev, Henrik; Hoekzema, A.J.; Hughes, Thomas P.; Davies, Poul; Gatcombe, Christopher; Woskov, Paul P. // Review of Scientific Instruments;Jan1999, Vol. 70 Issue 1, p1167 

    Describes the calibration of the receiver of the Joint Experimental Torus tokamak energetic ion and alpha particle collective Thomson scattering diagnostic. Calibration of the 32 receiver channels with a mechanical chopper in the quasioptical arm of the receiver; Noise associated with the...

  • Interactive optical design and realization of an optimized charge coupled device Thomson... Walsh, M.J.; Conway, N.J.; Dunstan, M.; Forrest, M.J.; Huxford, R.B. // Review of Scientific Instruments;Jan1999, Vol. 70 Issue 1, p742 

    Describes the successful implementation of a high resolution, multipoint Thomson scattering system on the START tokamak. Incorporation of a ruby laser system with a gated image intensifier and a charge-coupled device; Range of temperatures measured; Spatial resolution; Interactive design of the...

  • Performance of Alcator C-Mod core Thomson scattering system. Mossessian, D.A.; Hubbard, A.; Irby, J. // Review of Scientific Instruments;Jan1999, Vol. 70 Issue 1, p759 

    Discusses the design of the Alcator C-Mod Thomson scattering diagnostic. System description and data analysis procedure; Calibration and comparison with other diagnostics; Components providing the beam alignment stability and reliable electron density measurements.

  • A Thomson scattering diagnostic for measurements in the divertor region of TCV. Behn, R.; Rommers, J.H.; Pitts, R.A.; Pietrzyk, Z.A.; Chavan, R.; Marletaz, B. // Review of Scientific Instruments;Jan1999, Vol. 70 Issue 1, p768 

    Proposes a Thomson scattering system for measurements of electron temperature and density in the divertor region of the TCV tokamak. Thomson scattering system for main plasma; Special features of the divertor system; Spectral analysis of the scattered region; Optimization of system parameters...