TITLE

Neutron activation measurements over an extremely wide dynamic range (invited) (abstract)

AUTHOR(S)
Barnes, Cris W
PUB. DATE
January 1997
SOURCE
Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p520
SOURCE TYPE
Academic Journal
DOC. TYPE
Abstract
ABSTRACT
Presents an abstract of a paper discussing absolutely calibrated neutron yield measurements over an extremely wide dynamic range using dosimetric reactions with thin elemental foils. International Thermonuclear Experimental Reactor burn durations; Thin foil techniques' lack of the sensitivity required at low fluences.
ACCESSION #
630767

 

Related Articles

  • Measurements and simulations of the neutron production at W7-AS. Wolle, B.; Weller, A.; Schill, S.; Gadelmeier, F.; Baloui, T.; Beikert, G. // Review of Scientific Instruments;Jan1999, Vol. 70 Issue 1, p1197 

    Presents the results of neutron counter calibration campaigns at the W7-AS stellarator. Neutron counters comprising the neutron diagnostic system of the stellarator; Calibration of the counters in situ using a [sup 238]Pu/B neutron source placed at discrete points inside the vacuum vessel;...

  • Radiometric Complex with Gamma Spectrometers for Measuring the Characteristics of Neutron Fields at Nuclear-Physics Installations. Sevast'yanov, V.; Kovalenko, O.; Zelenov, D.; Orlov, A. // Measurement Techniques;Jun2013, Vol. 56 Issue 3, p314 

    A method for measuring the induced activity in neutron activation detectors using gamma spectrometers with scintillator and semiconductor detectors is introduced. The sensitivity of the gamma spectrometers is measured as a function of γ-ray energy over a range of 0.06-3 MeV.

  • Neutron diagnostics in compact helical system Isobe, M.; Sasao, M.; Osakabe, M.; Fujita, J.; Okamura, S.; Kumazawa, R.; Matsuoka, K.; Takahashi, C. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p532 

    Discusses the application of an efficient neutron diagnostic system to deuterium experiments on compact helical systems. Counter operation in stray magnetic field; Ion temperature measurement; Confinement study of neutral beam-injected fast ion.

  • Distinction between DD and DT neutrons in the TFTR neutron collimator (abstract) Bitter, M.; Johnson, L. C.; Ku, Long-Poe; Roquemore, A. L.; von Goeler, S. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p552 

    Presents an abstract of a paper discussing the distinction between contributions from deuterium-deuterium and deuterium-tritium neutrons in the analysis of data from the Tokamak Fusion Test Reactor (TFTR) neutron collimator. Nature of TFTR discharges; Description of a multilayered plastic...

  • In-vessel calibration of the JET neutron monitors using a 252Cf neutron source: Difficulties experienced. Jarvis, O. N.; Sadler, G.; van Belle, P.; Elevant, T. // Review of Scientific Instruments;Oct90, Vol. 61 Issue 10, p3172 

    The most direct method of obtaining an absolute calibration of the set of fission chambers used at JET for the measurement of the time-resolved neutron yield is by means of a standardized [sup 252]Cf radio-isotope neutron source which is moved around the vacuum vessel to map out the volume...

  • In situ calibration of neutron detectors on TEXTOR. Hoenen, F.; Euringer, H.; Bosch, H. S.; Alevra, A. V.; Klein, H.; Delvigne, T. // Review of Scientific Instruments;Mar92, Vol. 63 Issue 3, p1945 

    Neutron yield measurements are performed at the Jülich Tokamak experiment TEXTOR with different detectors located around the Tokamak and on center axis above the shielding roof. Due to the large structure of the machine and the extended diagnostic equipment, both virgin and scattered neutrons...

  • Use of daily detector verification data for isotopical half-life determination. Gonçalves, Vitor C.; Zahn, Guilherme S.; Genezini, Frederico A.; Ticianelli, Regina B.; Saiki, Mitiko // AIP Conference Proceedings;May2013, Vol. 1529 Issue 1, p113 

    In this work, the possibility of using data fromthe daily detector verification routines performed at the Neutron Activation Laboratory of IPEN to determine precise values for the half-lives of 57Co and 60Co was evaluated. For this purpose data from 4 of the laboratory's detectors, some spanning...

  • Experimental Study of the Deformation of Instantaneous Neutron Spectra from the Fission of 235U Nuclei in Fast-Reactor Core Materials. Sevast’yanov, V.; Koshelev, A.; Maslov, G. // Instruments & Experimental Techniques;Jul/Aug2005, Vol. 48 Issue 4, p433 

    The results from studies of the deformation of the instantaneous neutron spectra resulting from the fission of 235U nuclei in the material of structural elements of a fast reactor core are presented. The neutron spectra at and near the center of the reactor core were measured using neutron...

  • High aspect ratio composite structures with 48.5% thermal neutron detection efficiency. Shao, Q.; Voss, L. F.; Conway, A. M.; Nikolic, R. J.; Dar, M. A.; Cheung, C. L. // Applied Physics Letters;2/11/2013, Vol. 102 Issue 6, p063505 

    The pillar structured thermal neutron detector is based on the combination of high aspect ratio silicon p-i-n pillars surrounded by the neutron converter material 10B. By etching high aspect ratio pillar structures into silicon, the result is a device that efficiently absorbs the thermal neutron...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics