TITLE

Electron cyclon emission imaging of electron temperature profiles and fluctuations (invited)(abstract)

AUTHOR(S)
Cima, G.; Deng, B.; Domier, C. W.; Geck, W. R.; Hsia, R. P.; Liang, C.; Jiang, F.; Luhmann, Jr., N. C.; Brower, D.; Watts, C.
PUB. DATE
January 1997
SOURCE
Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p408
SOURCE TYPE
Academic Journal
DOC. TYPE
Abstract
ABSTRACT
Presents an abstract of a paper that focuses on electron cyclotron emission (ECE) imaging of electron temperature profiles and fluctuations. Reasons why ECE is a powerful diagnostic in a high performance/high magnetic field, magnetic confinement experiment; Description of the device.
ACCESSION #
630731

 

Related Articles

  • Frequency and angular distribution of electron cyclotron emission at high temperatures (100–500 keV). Bornatici, M.; Ruffina, U.; Spada, M. // Physics of Fluids B: Plasma Physics;May90, Vol. 2 Issue 5, p874 

    The distribution of the electron cyclotron emission with respect to both the frequency and the viewing angle is analyzed for a loss-cone as well as an anti-loss-cone electron distribution function at temperatures between 100 and 500 keV. The accuracy of two approximate formulas for the...

  • Commissioning of electron cyclotron emission imaging instrument on the DIII-D tokamak and first data. Tobias, B.; Domier, C. W.; Liang, T.; Kong, X.; Yu, L.; Yun, G. S.; Park, H. K.; Classen, I. G. J; Boom, J. E.; Donné, A. J. H.; Munsat, T.; Nazikian, R.; Van Zeeland, M.; Boivin, R. L.; Luhmann, N. C. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10D928 

    A new electron cyclotron emission imaging diagnostic has been commissioned on the DIII-D tokamak. Dual detector arrays provide simultaneous two-dimensional images of Te fluctuations over radially distinct and reconfigurable regions, each with both vertical and radial zoom capability. A total of...

  • New ECE diagnostics for the TEXTOR-94 tokamak. Udintsev, V. S.; van de Pol, M. J.; Donné, A. J. H.; Oosterbeek, J. W.; Kra¨mer-Flecken, A. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p359 

    To aid the scientific research program on the Toroidal Experiment for Technology Oriented Research (TEXTOR)-94 tokamak, the existing electron cyclotron emission (ECE) diagnostics for the electron temperature studies are being extended with new systems that feature a good temporal and radial...

  • ECE imaging of electron temperature and electron temperature fluctuations (invited). Deng, B. H.; Domier, C. W.; Luhmann, N. C.; Brower, D. L.; Cima, G.; Donné, A. J. H.; Oyevaar, T.; van de Pol, M. J. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p301 

    Electron cyclotron emission imaging (ECE imaging or ECEI) is a novel plasma diagnostic technique for the study of electron temperature profiles and fluctuations in magnetic fusion plasma devices. Instead of a single receiver located in the tokamak midplane as in conventional ECE radiometers,...

  • Improved operation of the Michelson interferometer electron cyclotron emission diagnostic on DIII-D Austin, M. E; Ellis, R F; Doane, J L; James, R A // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p480 

    Describes several techniques developed to increase the precision of Michelson interferometers in measuring electron cyclotron emission from tokamak plasmas. Description of the fast-scanning Michelson interferometer; Transmission line; Calibration; Data processing.

  • Electron Bernstein wave electron temperature profile diagnostic (invited). Taylor, G.; Efthimion, P.; Jones, B.; Munsat, T.; Spaleta, J.; Hosea, J.; Kaita, R.; Majeski, R.; Menard, J. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p285 

    Electron cyclotron emission (ECE) has been employed as a standard electron temperature profile diagnostic on many tokamaks and stellarators, but most magnetically confined plasma devices cannot take advantage of standard ECE diagnostics to measure temperature. They are either...

  • Hybrid electron cyclotron emission imaging array system for Texas experimental tokamak upgrade Hsia, R P; Deng, B H.; Geck, W R; Liang, C; Domier, C. W.; Luhmann, Jr, N C.; Brower, D. L; Cima, G // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p488 

    Describes the development, testing, and implementation of a novel wide bandwidth, low-cost, 20 channel hybrid Schottky diode mixer array-based imaging system for electron cyclotron emission diagnostics on the Texas experimental tokamak upgrade. Hybrid imaging array; Shielding; Intermediate...

  • Electron cyclotron emission imaging diagnostic system for Rijnhuizen Tokamak Project. Deng, B.H.; Hsia, R.P.; Domier, C.W.; Burns, S.R.; Hillyer, T.R.; Luhmann Jr., N.C.; Oyevaar, T.; Donne, A.J.H. // Review of Scientific Instruments;Jan1999, Vol. 70 Issue 1, p998 

    Describes the development of a 16-channel electron cyclotron emission (ECE) diagnostic system and its installation on the Rijnhuizen Tokamak Project for measuring plasma ECE. Achievement of high spatial resolution; Characteristics of the ECE imaging system sample volumes; Obtained wavenumber...

  • Electron cyclotron-electron Bernstein wave emission diagnostics for the COMPASS tokamak. Zajac, J.; Preinhaelter, J.; Urban, J.; Zacek, F.; Sestak, D.; Nanobashvili, S. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10D911 

    The COMPASS tokamak recently started operation at the Institute of Plasma Physics AS CR, v.v.i., Prague. A new 16-channel radiometer, operating alternatively in three frequency bands, has been designed and constructed. The system is prepared for detection of normal electron cyclotron emission...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics